Note: Speeds other than 10Gb/sec may not be supported by your 10Gb NIC.
2.3.3
Using a 10GBASE-T Category 6 or 6a Cable (RJ45)
If you are using a copper based solution using the RJ45 connector, a Category 6 or 6a Ethernet
cable is required, with a maximum length of 55 meters for Category 6 and 100 meters for Category
6a.
To connect the Appliance to an Ethernet network or directly to a device, connect one side of the
Category 6 Ethernet cable into a RJ45 port located on a 10 Gigabit Ethernet card at the back of the
unit. When the plug is in the correct position, a “click” should be heard. Connect the other side of
the cable to your Ethernet network or device.
2.4
Connecting the 6Gb SAS cables
The SAS bus on the Appliance is capable of running at speeds of up to 6Gbits/s. However, devices
that operate at slower speeds (1.5 Gbits/s and 3Gbits/s) can still be connected to this SAS bus. The
Appliance will automatically negotiate with these devices to obtain their optimal operating speed
upon power up. Each SAS wide port can support up to 4 phys.
Connect the SAS cable(s) to the Appliance as shown below, ensuring that connector is the correct
way up.
11