33
First Menu
Level
Mode Number
Second
Menu
Level
Value
Range
Mode Description and Instructions
5=Friday,
6=Saturday,
7=Sunday,
8=Everyday,
9=Weekdays,
10=Sat/Sun,
11=Mon/Wed/Fri,
12=Tue/Thu,
13=Tue-Sat.,
14=Mon-Thu,
15=Mon-Sat
Display and time source number 1 is used for alarm activation in multi-display clocks.
In addition to day-of-the-week combination codes, Mode 29 also accepts any day
combination. A value greater than 128 is treated as a binary command. Days of the
week are assigned the following binary numbers: Mon=1, Tue=2, Wed=4, Thu=8,
Fri=16, Sat=32 and Sun=64. Any combination of days may be selected by adding
their assigned numbers together and then adding 128 to that value. For example, if
Mon, Wed and Fri are required, then the value would be 149 (1+4+16+128=149).
30
1-99
1-99
Alarm Schedule Assignment
1=default
Each alarm entry is assigned a schedule number. If the assigned number equals the
active schedule number in Mode 37-1, then the alarm time and day-of-the-week
parameters are evaluated. By default, every alarm entry is assigned schedule 1. The
control program can also be used to change this parameter.
32
5
0-11
Alarm Zone Address
0-11 , 0=default
This value determines the alarm zone of this clock’s relays.
32
14
0-99
Auto Brightness Option
0 = disable optional auto brightness control,
1-99 optional auto brightness offset to all display intensity. This option is typically
used in areas where lighting conditions change such as video conferencing rooms and
communications centers.
See also Modes 3, 37-83 and 51-7.
32
16
0-1
Alarm master/slave control
0=disable (default),
1=enable remote alarms
Secondary clocks may follow the alarm sounding of a master clock. This allows one
clock to control the alarm sounding of several alert horns. For example, one master
clock could contain the alert horn schedule for the entire building. Several secondary
clocks with the alert horn option could be controlled by the alarm schedule of the
master clock. Both Master and secondary clocks must have Mode 32-16 enabled for