Page 7
Symptom Remedies
17.
Water leaks from the bottom of the
coffee brewer.
Inspect the tank, silicone tubing and fittings for leakage.
18.
The solenoid valve chatters or howls.
Check to make sure the internal wiring is correct. Inspect for loose, damaged or overheating wires or terminals. Repair or
replace wiring as necessary.
The coffee brewer should be connected to a cold water line only.
Copper tubing should not touch the coffee brewer, walls or cabinet. Position the tubes so that they are not touching anything.
Test the incoming water supply pressure. Water pressure should be between 30 and 80 psi. If the water pressure exceeds 80
psi, install a water pressure regulator and reduce the water pressure to 50 psi.
Water Hammer. Contact a plumber to correct this problem.
Test the solenoid valve. Replace it if necessary.
If the steps in this trouble shooting guide should fail to solve your problem, unplug the coffee brewer and contact your nearest Brewmatic
Representative or you can contact Brewmatic Company direct at 800-421-6860.
THIS TROUBLE SHOOTING GUIDE IS FOR THE INSTALLERS USE ONLY.
OPERATOR SHOULD REFER TO THE OPERATING INSTRUCTION ONLY
RETROFIT BICA DIAL ADJUSTMENT
A.
TO INSTALL (See Fig. 1)
1.
Remove item # 5, Knob
2.
Loosen timer Screw/washer combo. (2 Plcs)
3.
Install item #2, Plate Stationary Limiter under both Screw/washer combos.
4.
Install item #3 , Plate Adjustable Limiter under both Screw/washer combos. Rotate tab to a 2 O’-clock position.
5.
Tighten down both Screw/washer combos.
6.
Install item #4, Plate Cam on the timer “D” shape shaft. The plate should be at 11 O’-clock position.
7.
Reinstall the Knob.
B.
TO ADJUST THE DIAL RANGE (See Fig.1)
1.
Remove item # 5, Selector Knob
2.
Remove item #4, Plate Cam
3.
Loosen timer Screw/washer combo (2 Plcs).
4.
Rotate item #3, Plate Limiter :
a)
Clockwise to decrease the time (The user will be able to turn the knob to max 8-1/2).
b)
Counter-Clockwise to increase the time (The user will be able to turn the knob to a max of 12)
5.
Tighten down screw/washer combo.
6.
Reinstall the Cam Plate.
7.
Reinstall the Selector Knob.
Fig. 1