background image

Page 6 

 

Symptom Remedies 

8.

 The beverage level is inconsistent. 

Inspect and clean the spray head, silicone tubing and fittings. 
Test the timer. Replace it if necessary. 
Test the water-incoming water supply for inconsistent water pressure. If the water pressure is inconsistent, install a water 

pressure regulator and reduce the water pressure to minimize water pressure fluctuations. 
Some types of water filtering systems may affect the water supply pressure and cause inconsistent beverage levels. If 

necessary, switch to the normal water supply and add an inline water filter. 
If present, check any in-line water filters. Check valves or shut-off valve for proper operation or blockage. 

9.

 The brewing cycle is too slow. 

Inspect and clean the spray head, silicone tubing and fittings. 
The flow control washer should be .06 gpm. Incorrect flow washers can cause inaccurate beverage levels. 
Inspect, clean or replace the flow washer and screen. 
Test the timer. Replace it if necessary. 
Test the incoming water supply pressure.  Water pressure should be between 30 and 80 psi.   

10. 

The brewing temperature is either too hot 

or too cold.

 

Adjust or replace thermostat. Turn the adjustment screw counter-clockwise to increase the temperature, clockwise to 

decrease. Turn the adjustment screw a maximum or 1/8 turn per adjustment. Retest and adjust again if necessary. The 
recommended temperature is between 192

°

 and 196

°

F. Test below the brew cone with water only. 

The flow control washer should be .06 gpm. Incorrect flow washers can cause inaccurate beverage levels. 
Test the incoming water supply pressure.  Water pressure should be between 30 and 80 psi.  If the water pressure exceeds 80 

psi, install a water pressure regulator and reduce the water pressure to 50 psi. 

WARNING 

If the thermostat cannot be adjusted properly, it should be replaced. The thermostat is calibrated at the factory and no 

attempt should be made to recalibrate it. Use only original authorized replacement parts.

 

11.

 The water flow starts and stops during 

the brew cycle.

 

Test the “Power-Off-Fill “ Switch. Replace it if necessary. 
Test the solenoid Relay. Replace it if necessary. 
Test the “Power-Off-Fill” switch. Replace it if necessary. 

12.

 The brewing cycle starts by itself.

 

Test the “Power-Off-Fill “ Switch. Replace it if necessary. 
Test the solenoid valve for leaks. Replace it if necessary. 
Test the timer. Replace it if necessary. 
Check to make sure the internal wiring is correct. Inspect for loose, damaged or overheating wires or terminals. Repair or 

replace wiring as necessary. 
Test the incoming water supply pressure.  Water pressure should be between 30 and 80 psi.  If the water pressure exceeds 80 

psi, install a water pressure regulator and reduce the water pressure to 50 psi. 

13.

 The brew cycle continues even after the 

knob has reached off.

 

Test the “Power-Off-Fill “ Switch. Replace it if necessary. 
Test the timer. Replace it if necessary. 
Check to make sure the internal wiring is correct. Inspect for loose, damaged or overheating wires or terminals. Repair or 

replace wiring as necessary. 

Test the incoming water supply pressure.  Water pressure should be between 30 and 80 psi.  If the water pressure exceeds 80 

psi, install a water pressure regulator and reduce the water pressure to 50 psi. 

14.

 The water drips from the spray head after 

the knob is off.

 

Inspect and clean the spray head, silicone tubing and fittings. 
Test the solenoid valve for leakage. 

Test the incoming water supply pressure.  Water pressure should be between 30 and 80 psi.  If the water pressure exceeds 80 

psi, install a water pressure regulator and reduce the water pressure to 50 psi. 

15.

 The coffee brewer steams through the 

spray head..

 

Clean the spray head. 
Test the brewing temperature. Adjust it if necessary. (See page 8). 
Inspect, clean or replace the flow washer and screen. 
The flow washer should be .06 gpm. 
Clean or replace the tank assembly. 

16.

 Parts are failing frequently.

 

Check to make sure the internal wiring is correct. Inspect for loose, damaged or overheating wires or terminals. Repair or 

replace wiring as necessary. 
Test the voltage supply. The voltage supply should match the voltage requirement on the electrical nameplate. 
Test the wall receptacle for correct polarity. 
Use original or authorized, replacement parts. 

 

 

Summary of Contents for 1033510

Page 1: ...wer Models 1033510 1033510S 1033511 3828 S Main St Los Angeles CA 90037 1491 800 421 6860 310 787 5444 Fax 310 787 5412 e mail brew_equip brewmaticusa com FM CS104 Rev A 12 10 2004 Instruction Number 9600107 P P a a r r t t s s S S e e r r v v i i c c e e ...

Page 2: ...ons are subject to change without notice Due to periodic reviews and changes in listing standards listings and approvals may change at any time For current listing and approval information contact Brewmatic Plumbing connections All plumbing connections to water supply lines and drains should be performed by a licensed plumber complying with all applicable plumbing codes having jurisdiction Electri...

Page 3: ...ers 1800510 Description Single Unit Warmer Description Built In Warmer Volts 120 Volts 120 Watts 90 Watts 100 Power Supply Cord 3 Ft 2 Wire Ground 15 Amp 18 AWG Power Supply Cord None Outlet Box Supplied for direct wiring Plug NEMA 5 15P Furnished and Attached Listing UL Listing UL NSF NOTE Model 1033510 is no longer in production CONTROL LOCATIONS AND DESCRIPTIONS 1 Brewing Light Indicates that t...

Page 4: ...Page 4 WIRING DIAGRAM Built In Coffee Appliance WIRING DIAGRAM 1800508 Single Unit Warmer WIRING DIAGRAM 1800510 Built In Warmer ...

Page 5: ... or overheating wires or terminals Repair or replace wiring as necessary 4 The brewing cycle does not start The unit heats or steams Test the thermostat Replace it if necessary Inspect clean or replace the flow washer and screen Test the Power Off Fill Switch Replace it if necessary Test the solenoid valve Replace it if necessary If present check any in line water filters check valve or shut off v...

Page 6: ... Test the Power Off Fill Switch Replace it if necessary Test the solenoid Relay Replace it if necessary Test the Power Off Fill switch Replace it if necessary 12 The brewing cycle starts by itself Test the Power Off Fill Switch Replace it if necessary Test the solenoid valve for leaks Replace it if necessary Test the timer Replace it if necessary Check to make sure the internal wiring is correct I...

Page 7: ...nd contact your nearest Brewmatic Representative or you can contact Brewmatic Company direct at 800 421 6860 THIS TROUBLE SHOOTING GUIDE IS FOR THE INSTALLERS USE ONLY OPERATOR SHOULD REFER TO THE OPERATING INSTRUCTION ONLY RETROFIT BICA DIAL ADJUSTMENT A TO INSTALL See Fig 1 1 Remove item 5 Knob 2 Loosen timer Screw washer combo 2 Plcs 3 Install item 2 Plate Stationary Limiter under both Screw wa...

Page 8: ...lowed before attempting to adjust this equipment WARNING Turn off the Power Off Fill switch unplug the power supply cord and allow the coffee brewer to cool before servicing unless electrical testing is required Note Allow the coffee brewer to heat up to brewing temperature before testing this equipment WARNING Under no circumstance should the hi limit thermostat be by passed In the event of failu...

Page 9: ...sket Copper 17 9922244 Valve Solenoid 9906431 Flow Washer 06 GPM CAD 18 9915115 O Ring 19 9915158 O Ring 20 9906449 Fitting Nut Hose Reducer 21 9906154 Fitting Elbow 1 4 Flare 22 9906103 Nut 1 4 Flare 23 9205102 Nut Dampening 8 32 24 9918245 Relay 25 9007106 Screw 8 x 1 4 26 9920429 Relay 27 1039081 Kit Timer Dial Adjustment 28 9911161 Knob 12 Cup 29 9916246 Pilot Light Red 30 1040769 Facia Black ...

Page 10: ...6 Bushing Strain Relief 10 9903487 Cord Power Supply 11 9301183 Washer Rubber 12 6000397 Bushing Thermal 13 9001142 Screw 6 32 x 7 8 14 6000398 Foot Cork PARTS DIAGRAM PARTS LIST 1800510 Built In Warmer Item No Part No Description 1 6003093 Element Pan Assy Black Complete 2 9919432 Switch Lighted Rocker Without Bezel 3 9902331 Bezel Switch 4 9001110 Screw Bracket 8 32 x 1 5 9303123 Washer Lock 8 S...

Page 11: ...20333 S Normandie Ave Torrance CA 90502 310 787 5444 800 421 6860 Fax 310 787 5412 USA E mail brew brewmaticusa com Int l E mail brew_equip brewmaticusa com Website brewmatic com ...