background image

Page 2 

 

IMPORTANT INFORMATION & SAFEGUARDS 

Read all instructions and safeguards included in the packaging carefully and completely before installing or operating this equipment.  Save all instructions for future 

reference. 
To reduce the risk of fire or electric shock, do not remove covers.  There are no user serviceable parts inside.  Repairs should be done by authorized service personnel 

only.  If this appliance should fail to operate properly, contact the nearest Brewmatic Authorized Service Center or you can contact Brewmatic  direct at 800-421-6860. 

Only Authorized Replacement Parts Should Be Used.

  Part substitutions could create a fire hazard and the risk of personal injury.  The use of replacement parts or 

accessory attachments not recommended by Brewmatic may be hazardous. 

Do Not By-Pass Any Safety Mechanisms Or Operate This Appliance Without Covers In Place.

  Brewmatic requires that all safety devices and covers be in place and 

functioning at all times to guard against a fire hazard and the risk of personal injury. 
Do not touch hot surfaces. Use handles or knobs whenever possible. 
Do not let power cord hang over the edge of table, counter or touch hot surfaces. Close supervision is necessary when any appliance is used by or near children. 
Do not use outdoors. Do not use appliance for other than intended use. 
Do not operate any appliance with a damaged cord or plug or after the appliance malfunctions, or has been damaged in any manner. Return appliance to the nearest 

authorized service facility for examination, repair or adjustment. 
The container is designed for use with this appliance. It must never be used on a range top.(Unless specific instructions for use on a range top are provided and include 

the precautions to be observed.) Do not set a hot container on a cold surface. Do not use a cracked container or a container having a loose or weakened handle. Do not 

clean container with cleansers, steel wool pads, or other abrasive material. 

Brewmatic Does Not Recommend, And Will Not Furnish Anyone With Information For Changing The Electrical Rating Of Any Appliance Manufactured Or Distributed 

By Brewmatic .

  Brewmatic will not approve of any unauthorized changes to the basic design of this appliance.  Any modification or alteration to the appliance may create 

a fire hazard, may create a risk of personal injury, may void the safety listings and may void the warranty. 
All procedures, diagrams and specifications contained in this manual are based on the latest information available at the time of publication.  Information, parts and 

specifications are subject to change without notice. 
Due to periodic reviews and changes in listing standards, listings and approvals may change at any time.  For current listing and approval information contact Brewmatic. 

Plumbing connections - 

All plumbing connections to water supply lines and drains should be performed by a licensed plumber complying with all applicable plumbing 

codes having jurisdiction. 

Electrical connections - 

With the exception of cords with plugs already attached, all electrical connections or alterations to the Power/Off/Fill supply should be performed 

by a licensed electrician complying with all applicable electrical codes having jurisdiction. 
When calling for information, parts or service, have the following information available: 

Model Number:  

 Serial Number:  

 

Voltage:  

 Amps:  

 Phase:  

  

Date Of Purchase:_____________________________ 

Electrical information may be obtained from the electrical information nameplate located on the appliance.

 

 

SAVE THESE INSTRUCTIONS 

 

LIMITED WARRANTY 

Brewmatic warrants this product to be free of defects in material and workmanship for a period of one (1) year from the original date of purchase.  Within this warranty 

period, Brewmatic will repair or replace, at its option, any part providing it's defective in material or workmanship.  Labor is included within this warranty only during the 

first ninety (90) days of the warranty period. 

This warranty excludes defects caused by negligence, misuse, alteration, accident, prior service by unauthorized persons, and failure to follow the installation and 

operating instructions, including without limitation use of improper voltage or wiring and improper cleaning. 

This warranty applies only to new products and extends only to the original purchaser.  This warranty is valid only in the United States of America and its possessions. 

The product warranted hereby is sold only for commercial use and is not intended for personal, family, or household purposes. 

To obtain warranty service, you must notify and deliver the product at your expense, with proof of purchase, to your local Brewmatic representative or to the Brewmatic 

Customer Service Division, within the warranty period.  The repaired product will be returned to you at Brewmatic's expense. 

No Brewmatic representative or other person is authorized to add to or alter the foregoing in any respect. 

THE FOREGOING WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTIES FOR MERCHANTABILITY 

AND FITNESS FOR A PARTICULAR PURPOSE.  THIS WARRANTY EXCLUDES CONSEQUENTIAL DAMAGES. 

Some states do not allow limitation or exclusion of implied warranties or consequential damages.  In such cases the limitations stated above may not apply to you, and 

your rights will be determined by applicable law. 

Summary of Contents for 1033510

Page 1: ...wer Models 1033510 1033510S 1033511 3828 S Main St Los Angeles CA 90037 1491 800 421 6860 310 787 5444 Fax 310 787 5412 e mail brew_equip brewmaticusa com FM CS104 Rev A 12 10 2004 Instruction Number 9600107 P P a a r r t t s s S S e e r r v v i i c c e e ...

Page 2: ...ons are subject to change without notice Due to periodic reviews and changes in listing standards listings and approvals may change at any time For current listing and approval information contact Brewmatic Plumbing connections All plumbing connections to water supply lines and drains should be performed by a licensed plumber complying with all applicable plumbing codes having jurisdiction Electri...

Page 3: ...ers 1800510 Description Single Unit Warmer Description Built In Warmer Volts 120 Volts 120 Watts 90 Watts 100 Power Supply Cord 3 Ft 2 Wire Ground 15 Amp 18 AWG Power Supply Cord None Outlet Box Supplied for direct wiring Plug NEMA 5 15P Furnished and Attached Listing UL Listing UL NSF NOTE Model 1033510 is no longer in production CONTROL LOCATIONS AND DESCRIPTIONS 1 Brewing Light Indicates that t...

Page 4: ...Page 4 WIRING DIAGRAM Built In Coffee Appliance WIRING DIAGRAM 1800508 Single Unit Warmer WIRING DIAGRAM 1800510 Built In Warmer ...

Page 5: ... or overheating wires or terminals Repair or replace wiring as necessary 4 The brewing cycle does not start The unit heats or steams Test the thermostat Replace it if necessary Inspect clean or replace the flow washer and screen Test the Power Off Fill Switch Replace it if necessary Test the solenoid valve Replace it if necessary If present check any in line water filters check valve or shut off v...

Page 6: ... Test the Power Off Fill Switch Replace it if necessary Test the solenoid Relay Replace it if necessary Test the Power Off Fill switch Replace it if necessary 12 The brewing cycle starts by itself Test the Power Off Fill Switch Replace it if necessary Test the solenoid valve for leaks Replace it if necessary Test the timer Replace it if necessary Check to make sure the internal wiring is correct I...

Page 7: ...nd contact your nearest Brewmatic Representative or you can contact Brewmatic Company direct at 800 421 6860 THIS TROUBLE SHOOTING GUIDE IS FOR THE INSTALLERS USE ONLY OPERATOR SHOULD REFER TO THE OPERATING INSTRUCTION ONLY RETROFIT BICA DIAL ADJUSTMENT A TO INSTALL See Fig 1 1 Remove item 5 Knob 2 Loosen timer Screw washer combo 2 Plcs 3 Install item 2 Plate Stationary Limiter under both Screw wa...

Page 8: ...lowed before attempting to adjust this equipment WARNING Turn off the Power Off Fill switch unplug the power supply cord and allow the coffee brewer to cool before servicing unless electrical testing is required Note Allow the coffee brewer to heat up to brewing temperature before testing this equipment WARNING Under no circumstance should the hi limit thermostat be by passed In the event of failu...

Page 9: ...sket Copper 17 9922244 Valve Solenoid 9906431 Flow Washer 06 GPM CAD 18 9915115 O Ring 19 9915158 O Ring 20 9906449 Fitting Nut Hose Reducer 21 9906154 Fitting Elbow 1 4 Flare 22 9906103 Nut 1 4 Flare 23 9205102 Nut Dampening 8 32 24 9918245 Relay 25 9007106 Screw 8 x 1 4 26 9920429 Relay 27 1039081 Kit Timer Dial Adjustment 28 9911161 Knob 12 Cup 29 9916246 Pilot Light Red 30 1040769 Facia Black ...

Page 10: ...6 Bushing Strain Relief 10 9903487 Cord Power Supply 11 9301183 Washer Rubber 12 6000397 Bushing Thermal 13 9001142 Screw 6 32 x 7 8 14 6000398 Foot Cork PARTS DIAGRAM PARTS LIST 1800510 Built In Warmer Item No Part No Description 1 6003093 Element Pan Assy Black Complete 2 9919432 Switch Lighted Rocker Without Bezel 3 9902331 Bezel Switch 4 9001110 Screw Bracket 8 32 x 1 5 9303123 Washer Lock 8 S...

Page 11: ...20333 S Normandie Ave Torrance CA 90502 310 787 5444 800 421 6860 Fax 310 787 5412 USA E mail brew brewmaticusa com Int l E mail brew_equip brewmaticusa com Website brewmatic com ...

Reviews: