BIAC User Manual Installation
intended for a regular operating staff, which must be properly trained. Regarding any emergency
or scheduled maintenance, the contained information is intended for professional staff only.
Cleaning and Maintenance
Before any work on the machine, it must be disconnected from the main electrical supply.
Before the machine is cleaned, it must be disconnected from the main electrical supply. Cleaning
of the condenser (No. 7 in Figure 44) must be performed only by a qualified person at least 1x
per month by sweeping or by CO2 pressure. Perform the cleaning (sanitizing) of the stainless
steel coil (No. 10 in Figure 44) professionally with the use of a cleaner such as DOPILINE or TM
Desana solution, and always after a minimum of fourteen days.
To clean the condensor, the fan cover (No. 6 in Figure 44) can be removed from the metal slides
by pulling upwards (See Figure 51).
Remove the fan from the cover.
Remove the fastening screws from the chiller on the side where the condenser is placed.
(picture 3.1 and 3.2 in Figure 52)
First, pull out the loose cover about 3 cm in a upward direction (picture 4.1.), then pull to the side
(pic. 4.2). Loosen the other side of the cover so you can pull out the whole cover from the metal
slides. (See Figure 52)
Now the condenser can be cleaned by gently brushing or by use of air pressure from both sides.
For routine maintenance:
• Check, if the power supply plug is firmly plugged into the socket.
• Check that the machine is not exposed to radiant heat.
• Check the level and cleanliness of the water bath in the plastic container (No. 11 in Figure
44) and after a maximum of six months of operation replace the water bath.
• The condenser of the cooling unit should be cleaned regularly.
• When sanitizing beer lines do not forget to also sanitize the dispensing tap and the
dispense head. You need to disassemble them, then soak in a chemical solution and clean
thoroughly to remove any residue left by the beer.
Warning: If the grey ring is not pressed down while pulling out the tube, the
fitting will bind even more tightly to the tube making removal even harder.
Warning: Ensure the tube is not under pressure when disconnecting.