Document # 2103017 RevA 

Printed in USA © 2017

Complete the “

Operating Test

”.

Test Failed                           Test Passed

Test complete

Call Brewer Tech Support 888-Brewer-1.

Call Brewer Tech Support 888-Brewer-1.

No movement

Go to step 2.1

Some movement

Go to step 2.2

Start

Step #

* No relay clicking in control box. Table then functions after about 30 minutes.

1

2

3

4

5

6

7

Do all powered functions work?

Yes                                                   No

Go to step 5.1

 for drawer warmer

Go to step 6.1 

for outlet.

Return to step 1

Go to step 7.1

Do the 6 front limit switches work 

properly?

Yes                                                   No

Front cabinet switches; 1 or more of 6 

not closing when pressed. Press each 

one and listen for click when pressed 

and again when released. Replace as 

necessary.

Fixed                       Problem remains

Seat back switches; 1 or more of 4 not 

opening when pressed. Press each 

one and listen for click when pressed 

and again when released. Replace as 

necessary.

Fixed                       Problem remains

Do the 4 seat back limit switches work 

properly?

Yes                                                   No

Does the drawer warmer heat prop-

erly, and does the outlet work?

Yes or N/A                                       No

Does the table stop operating after a 

period of heavy use? *see below

No                                                   Yes

Control box is over temperature. Allow 

30 minute cool down. Control box will 

reset automatically.

Is there excessive noise, or are there 

other problems which have not yet 

been identified?

No                                                   Yes

6000 SERIES TABLE TROUBLESHOOTING CHART

Summary of Contents for access high-low

Page 1: ...ument 2103017 RevA Printed in USA 2017 Troubleshooting Guide The Brewer Company LLC N88 W13901 Main Street Suite 100 Menomonee Falls WI 53051 P 1 888 Brewer 1 F 262 251 2332 www brewercompany com Brew...

Page 2: ...ntacting the back cabinet 2 Press the BACK DOWN pedal The back should go to the full recline position which is level 3 Press the BACK UP pedal The back should go to the full up position 4 Press the BA...

Page 3: ...f 6 not closing when pressed Press each one and listen for click when pressed and again when released Replace as necessary Fixed Problem remains Seat back switches 1 or more of 4 not opening when pres...

Page 4: ...r 5 minutes with switch in either position Is warmer warming up Yes No Check for loose wire connections at terminal block s if S N is less than HL002100 or if S N has a C at the end Check that all plu...

Page 5: ...ckrest movement powered back models Does motor hum in the up direction but there is no movement No Yes Backrest or lift stuck in the full up position No motor hum Do control box relays click in both u...

Page 6: ...luminate Yes No Replace warmer outlet fuse s at back of table on plate where foot control and power cord plug in Does outlet operate Yes No Replace warmer switch Does warmer switch illuminate Yes No R...

Page 7: ...ment not stopped by stop button or foot control pedals No Yes The backrest actuator return chair that protrudes from the center of the back of the seat section is defective or its wiring harness blue...

Reviews: