background image

10

WHAT IS THE AIRROUNDER PLUS™ 
CONNECT PURIFIER FAN HEATER?

The Breville AirRounder Plus™ Connect 
purifier fan heater features an air purifier, 
heater and cooling fan in one. 
The Purifier improves your indoor air quality 
using 3 distinct levels of protection.

1. A Pre-Filter

Captures larger airborne particles such as 
human hair, pet dander and dust particles.

2. A True HEPA Filter

Traps up to 99.97% of fine particles, allergens 
and airborne contaminants down to 
0.3 microns in size. These include bacteria, 
viruses, mould spores, plant spores, and pollen.

3. An Activated Carbon Membrane

Along with assisting in the capture of dust, 
smoke, pollen and other airborne allergens, the 
activated carbon membrane helps to neutralise 
odours in the home and to eliminate fumes 
emitted by household products as well as 
other volatile organic compounds (VOC’s) that 
might be found in the air.

Heating/Cooling Light Ring

Your purifier fan heater is fitted with a light 
ring that surrounds the head of the purifier 
fan heater that illuminates a blue colour when 
in cooling mode and a red colour when in 
heating mode.  

The light ring can be switched off at any time. 
Touch and hold the   button on the control 

panel for 3 seconds to turn off the light ring 
in any mode.

NOTE

The heating/cooling light ring should not be 
confused with the air quality light indicators on 
the control panel.

SAFETY FEATURES

Safety Tip-Over Cut-Out Switch

There is a tip-over switch inside the purifier 
fan heater. 
If the purifier fan heater is accidentally tipped 
over, the purifier fan heater will stop operating. 
Once placed back into the upright position, the 
purifier fan heater will switch on again.

THERMOSECURE™ Protection

Your purifier fan heater is fitted with a safety 
device that switches off the purifier fan heater 
in the event of overheating. Should this purifier 
fan heater stop working, turn off the purifier 
fan heater and inspect the air inlet and outlet 
for blockages. Wait until the purifier fan heater 
is fully cooled for the protection system to reset 
before attempting to restart the purifier fan 
heater. If the purifier fan heater fails to operate 
or the safety device switches off again, take the 
purifier fan heater to an authorised Breville 
Service Centre for examination or repair.

Features

LPH708_ANZ_IB_B21_FA.indd   10

LPH708_ANZ_IB_B21_FA.indd   10

29/1/21   11:04 am

29/1/21   11:04 am

Summary of Contents for the AirRounder Plus LPH708

Page 1: ...the AirRounder PlusTM Connect Instruction Book LPH708 LPH708_ANZ_IB_B21_FA indd 1 LPH708_ANZ_IB_B21_FA indd 1 29 1 21 11 04 am 29 1 21 11 04 am...

Page 2: ...pliances IMPORTANT SAFEGUARDS READ ALL INSTRUCTIONS BEFORE USE AND SAVE FOR FUTURE REFERENCE Carefully read all instructions before operating the purifier fan heater for the first time and save for fu...

Page 3: ...play with the purifier fan heater Do not use this purifier fan heater in the immediate surroundings of a bath a shower or a swimming pool Do not immerse or allow liquids to be spilt on the purifier fa...

Page 4: ...r positioned incorrectly This purifier fan heater is not intended for use in wet or moist locations To disconnect the purifier fan heater switch the power switch to OFF then switch off at the power ou...

Page 5: ...Breville or an authorized service agent for inspection or repair Do not unplug the purifier fan heater by pulling on the power cord Always unplug using the power plug To disconnect the purifier fan he...

Page 6: ...entre for examination and or repair Any maintenance other than cleaning should be performed at an authorised Breville Service Centre This appliance is for household use only Do not use this appliance...

Page 7: ...unplug at the power outlet and remove the power cord if detachable from the appliance and allow all parts to cool Do not place this appliance on or near a heat source such as hot plate oven or heater...

Page 8: ...rear cover NOT PICTURED Power Cord and Plug Remote Control Storage Non Slip Non Marking Rubber Feet A G I H C B F E D A B C E D REMOTE CONTROL PANEL A Power ON OFF Wi Fi button B Oscillation 60 C 120...

Page 9: ...n 60 C 120 C 360 C Filter Reset button C Cooling LOW MEDIUM HIGH Temp decrease Child Lock button D Heating LOW MEDIUM HIGH Temp increase Set Temp button E Power ON OFF Wi Fi button DISPLAY SCREEN A Am...

Page 10: ...heating mode The light ring can be switched off at any time Touch and hold the button on the control panel for 3 seconds to turn off the light ring in any mode NOTE The heating cooling light ring sho...

Page 11: ...ocation for the purifier fan heater For proper air flow locate the unit at least 20cm from any wall or furniture Ensure the air inlet and outlets are not blocked before use Ensure the filter has been...

Page 12: ...ING YOUR PURIFIER FAN HEATER Place the purifier fan heater on a flat surface Insert the power plug into a 230V or 240V power outlet and switch on at the outlet When switched on a chime will sound to c...

Page 13: ...operation is stopped the unit will enter standby mode and the LED display screen will illuminate OFF whilst the unit is cooling down Once cooled the ambient room temperature will be displayed WARNING...

Page 14: ...set the timer tap the button repeatedly on the control panel or press on the remote control until the desired number of hours displays on the control panel LED lights The timer will start on the sele...

Page 15: ...rformance the filter should be cleaned at least monthly as per the instructions found in the Care Cleaning Storage section of this book REMOTE CONTROL The purifier fan heater comes with a remote contr...

Page 16: ...urns and potential perforation of the oesophagus If you suspect your child has swallowed or inserted a button battery immediately call the 24 hour Poisons Information Centre on 13 11 26 for fast exper...

Page 17: ...ER TO WI FI 1 Ensure the mobile device is connected to a home Wi Fi network 2 The purifier fan heater can either be on standby mode or turned on when setting up The symbol will flash fast on the displ...

Page 18: ...damage the unit 8NEVER use alcohol or other solvents on this unit AIR QUALITY SENSOR CARE AND CLEANING It is important to keep the air quality sensor clean for best performance The air quality sensor...

Page 19: ...n cause damage Replace the filter as indicated using the following instructions REPLACING THE FILTER Your AirRounder Plus Connect purifier fan heater filter should be replaced in the time frames indic...

Page 20: ...operate REPLACEMENT FILTERS Replacement filters must be purchased from the Breville website or at participating retail outlets See the table below for the replacement product code to suit this Brevill...

Page 21: ...closed properly Check that the unit is on a level surface Light ring not illuminating Contact Breville service centre for replacement Not heating in the heating mode Check for any obstructions in the...

Page 22: ...the Breville Home Connect app Reset the purifier fan heater by pressing and holding the power button for 15 seconds The Wi Fi indicator will rapidly blink 10 times and turn off Re pair the purifier to...

Page 23: ...23 Note LPH708_ANZ_IB_B21_FA indd 23 LPH708_ANZ_IB_B21_FA indd 23 29 1 21 11 04 am 29 1 21 11 04 am...

Page 24: ...nt AirRounder Plus ThermoSecure SensAir System and Breville Home Connect are trademarks of Breville Pty Ltd A B N 98 000 092 928 Copyright Breville Pty Ltd 2021 Due to continued product improvement th...

Reviews: