background image

14

Care, Cleaning  
& Storage

The air purifier and AntiViral filter should be 

cleaned at least once a month. Ensure the air 

purifier is switched off and disconnected from 

the power outlet and allow all parts to cool 

before cleaning or storing.

• 

Use a clean, dry cloth to clean all external 

surfaces of the air purifier.

NOTE

More frequent cleaning may be required 

depending on environmental conditions.

BREVILLE RECOMMENDS

• 

Always ensure the air purifier is turned 

off, switched off at the power outlet and 

unplugged and allow the unit to cool before 

performing any cleaning, filter or UV-C 

replacement.

 

8

DO NOT

 stick any foreign objects or your 

fingers inside the air inlet/outlet of this unit.

 

8

DO NOT

 use gasoline, benzine, thinner, 

harsh cleaners, etc. on and/or in the unit 

while cleaning as they will damage the unit.

 

8

NEVER

 use alcohol or other solvents  

on this unit.

CLEANING THE SENSOR 

• 

It is important to keep the air quality sensor 

clean for best performance.  

• 

The air quality sensor is situated behind  

a grill at the rear of the unit.

• 

Gently vacuum the air quality sensor grill 

using a small hand brush tool.  Cleaning 

should occur regularly, at least once a month. 

FILTER CARE & CLEANING

WARNING

The filter is not washable. Do not immerse  

any part of the air purifier in water as it will 

cause damage. 

• 

The Pre-filter should be cleaned at least once a 

month using a vacuum cleaner. Gently vacuum 

using a hand-tool attachment such as a brush 

or upholstery tool. Clean more often if required.

• 

Do not attempt to clean the carbon filter with a 

vacuum as this can cause damage.

• 

Do not use any solutions, hard bristle  

brushes or sharp objects to clean as this  

can cause damage.

• 

Replace the filter as indicated using the 

following instructions.

REPLACING THE FILTER 

Your Breville

 

Purifier AntiViral Filter should be 

replaced in the time frames indicated below.

The Filter Reset

The purifier has a helpful filter replacement 

reminder to alert when the filter needs changing.

• 

The filter life is approximately 12 months 

based on 12 hours daily operation or 4320hrs.

• 

The filter life will vary based on environment 

conditions and more frequent change is 

required. For optimal performance change filter 

every 6 months.

• 

Remove all packaging from the replacement 

filter and place the filter into the unit as 

described below:

1.  With the purifier in an upright position, slide 

the toggle located on the base to the right to 

unlock. 

2.  Using both hands, lift the body of the purifier 

off the base and place the body aside. The 

filter will remain in position.

3.  Remove the used filter, being careful that any 

residue or debris that may fall from the filter 

will not cause damage.

Summary of Contents for LAP208

Page 1: ...the Smart AirTM Viral Protect Compact the Smart AirT M Viral Protect Plus Instruction Book LAP208 LAP408 ...

Page 2: ... 200m3 h Power Consumption 41W 44W Weight 3 15Kg 3 35Kg OS Compatibility Android 5 0 or later and iOS 11 or later Android 5 0 or later and iOS 11 or later IMPORTANT SAFEGUARDS READ ALL INSTRUCTIONS BEFORE USE AND SAVE FOR FUTURE REFERENCE Remove and safely discard any packaging material and promotional labels before using the air purifier and filter for the first time To eliminate a choking hazard...

Page 3: ...rill changing filters and cleaning or whenever the air purifier is not in use Do not unplug the air purifier by pulling on the power cord Always unplug using the power plug Never insert fingers pencils or any other objects through the guards whenever the power plug is connected in particular while the air purifier is switched on Do not run the power cord under carpeting or cover the power cord wit...

Page 4: ... Keep the air purifier and dust filters clean Follow the cleaning instructions provided in this book IMPORTANT SAFEGUARDS FOR ALL ELECTRICAL APPLIANCES Fully unwind the power cord before use Connect only to a 230V or 240V power outlet Do not let the power cord hang over the edge of a bench or table touch hot surfaces or become knotted To protect against electric shock do not immerse the power cord...

Page 5: ...cal circuit supplying the appliance See your electrician for professional advice During electrical storms the appliance should be disconnected from the power source at the wall socket to prevent any electrical surges that may arise during the storm and which may inadvertently cause damage to the appliance and its electronic componentry Always turn the appliance to the off position switch off at th...

Page 6: ... Control Panel C Main Housing Body D Air Quality Sensor back of purifier E Air Inlet A B C E D F G LAP208 LAP408 F 3 Layer HEPA 13 AntiViral Filter G Detachable Base Filter Holder Not Pictured Microbe Shield UV C Light Power Cord ...

Page 7: ... Control Panel A LED Screen including PM2 5 Micron Monitor B Power On Off and Filter Reset Button C Fan Speed includes 4 speed modes Low Medium High and Turbo D Auto Wi Fi C G B A D E F E Microbe Shield TM Night Mode F Timer up to 8 hours G Air Quality Sensor Light Ring ...

Page 8: ...ly discard any packaging material or promotional labels attached to your air purifier and filter Remove the filter from the air purifier see REPLACING THE FILTER in the Care Cleaning Storage section of this book remove the protective packaging then refit the filter into the purifier Select a flat and level location for the air purifier For proper air flow locate the unit at least 20cm from any wal...

Page 9: ...orts the concentration of ultra fine air particles through a dedicated LCD Grade Air Quality AQI Measured in PM2 5 Colour of Light 1 Very Good 33 Blue 2 Good 34 66 Yellow 3 Fair 67 99 Orange 4 Poor 100 Red AirQualityIndex Microbe ShieldTM NIGHT MODE The Microbe ShieldTM and Night Modes utilise the same button on the control panel Pressing the Microbe Shield TM NIGHT MODE button will cycle through ...

Page 10: ...ate to inform TIMER selected For continuous operation press the TIMER button repeatedly until there are no lights illuminated under the timer intervals AUTO MODE When in Auto mode the air purifier will automatically adjust the speed to help filter the air based on the sensor reading To set to Auto press the AUTO button until the light below AUTO illuminates Press the AUTO button again to turn Auto...

Page 11: ...onnection has also been activated for this appliance which will aid in the pairing process providing a higher success rate when pairing 1 Ensure the mobile device is connected to a home Wi Fi network 2 Once on standby mode the symbol will flash fast on the display panel The air purifier is now ready to connect 3 Log into your Breville Home Connect app account and stay on the Home page To add the p...

Page 12: ...voice command NOTE To control the purifier using the Amazon Alexa or Google Home Assistant app it must be plugged in to an active power outlet and turned on VOICE CONTROL WITH AMAZON ALEXA Before activating voice control with Amazon Alexa link the Breville Home Connect account to the Amazon Alexa app as per the instructions Amazon Alexa Recommended Voice Commands Supported Settings Amazon Alexa Vo...

Page 13: ...Filter Reset TIPS for Amazon Alexa and Google Home Assistants Configure Amazon Alexa or Google Home Assistant compatible devices with the Alexa or Google Home Assistant app if using or simply download onto your phone You will find your device listed as the Breville product name in your Breville Home Connect app account Tap on the device in the app to rename your device for more convenient voice co...

Page 14: ...ot immerse any part of the air purifier in water as it will cause damage The Pre filter should be cleaned at least once a month using a vacuum cleaner Gently vacuum using a hand tool attachment such as a brush or upholstery tool Clean more often if required Do not attempt to clean the carbon filter with a vacuum as this can cause damage Do not use any solutions hard bristle brushes or sharp object...

Page 15: ...e of the purifier and carefully turn the body over for access 2 Using a screwdriver turn the screw anti clockwise until the UV C cage loosens about halfway 3 Turn the UV C cage anti clockwise to unlock and remove from the body 4 Gently unscrew the UV C light bulb to remove and replace with the new UV C light bulb 5 Place the UV C cage over the light bulb and turn clockwise ensuring the screw is al...

Page 16: ...is fitted correctly in place Insufficient air flow Check that the filters are clean Check for any obstructions in the air inlet and or outlet Excessive noise Check for any foreign objects that may be in contact with the fan Check if the filter is clogged and ready for replacement Check that the air purifier has been assembled correctly and the locking knob has been tightened Check that the unit is...

Page 17: ...ar and there is no unwanted noise in the background While the voice assistant is always on in the background only an activation phrase will allow for the voice assistant to start registering the commands being relayed The activation phrase depends on the application being used For Amazon Alexa use Alexa while OK Google is for Google Home Assistant Ensure your voice is clear and distinct to allow t...

Page 18: ...18 Notes ...

Page 19: ...19 Notes ...

Page 20: ...er Every Moment Smart Air Breville Home Connect SensAir and the Microbe Shield logo are trademarks of Breville Pty Ltd A B N 98 000 092 928 Copyright Breville Pty Ltd 2022 All other brands may be trademarks of their respective owners Due to continued product improvement the products illustrated photographed in this booklet may vary slightly from the actual product LAP208 LAP408 ANZ A22 ...

Reviews: