13

3.  The humidifier will continue to monitor 

and regulate as required to maintain the 

comfort zone, adjusting the mist intensity. 

Once the comfort zone has been achieved, 

the humidifier will stop the mist intensity 

automatically and will then operate 

again if the humidity level falls below the 

comfort zone.

4.  If the Timer has not been programmed, the 

humidifier will continue to operate in FULL 

AUTO mode until turned off manually, 

programmed to another mode or when the 

water tank is empty.

NOTE

The room temperature shown on the display 

screen is taken only within the vicinity of the 

sensor and may be influenced by positioning, 

airflow and other environmental factors. Actual 

room temperature may vary slightly.

SEMI-AUTO MODES

This humidifier can achieve 2 semi-

auto modes: ADJUSTABLE SPEED and 

ADJUSTABLE HUMIDITY modes.

• 

In ADJUSTABLE SPEED mode, the 

humidifier automatically keeps the humidity 

in the comfort zone with the SensAir 

System™ while the mist intensity can be 

manually selected.

• 

In ADJUSTABLE  HUMIDITY mode, the 

humidifier automatically adjusts the mist 

intensity to maintain a pre-selected relative 

humidity level.

• 

ADJUSTABLE SPEED and ADJUSTABLE 

HUMIDITY can only be accessed when the 

humidifier is on FULL AUTO mode.

• 

The Timer, Night mode, Warm Mist and ION 

features can be used with these modes.

ADJUSTABLE HUMIDITY

To program ADJUSTABLE HUMIDITY, 

touch the   HUMIDITY/NIGHT symbol 

on the control panel repeatedly to cycle 

through until the desired RH flashes on the 

display screen. The RH number will flash 3 

times then illuminate. The   FULL AUTO 

icon will illuminate and the % icon will 

flash continuously during this setting. The 

humidifier will start automatically if the room 

humidity is lower than the selected humidity. If 

the room humidity is higher than the selected 

humidity, ‘HI’ will display on the display screen, 

and mist will not be released.

NOTE

The humidity level can be selected in 5% 

increments between 30% and 90%. 
The mist intensity level will not illuminate as 

it will automatically modulate to achieve the 

desired humidity level.
Once the chosen relative humidity has been 

reached, the mist will stop releasing and will 

automatically restart once the humidity level 

falls below the set humidity.

ADJUSTABLE SPEED

To program ADJUSTABLE SPEED, 

touch or slide your finger along the 

 MIST LEVEL 

CONTROL bar on the control panel to change 

the mist intensity as desired. The mist intensity 

level will display and the on the right-hand 

side of the display screen, the mist intensity 

level will illuminate. The humidifier will start 

automatically if the room humidity is lower 

than the comfort zone.
If the ideal relative humidity is higher than the 

ideal humidity in the “Comfort Zone” , ‘HI’ will 

display on the display screen and adjustable 

speed cannot be programmed.

NOTE

The mist intensity level can be selected from 

LOW (1) to HIGH (5).
The room temperature and relative humidity 

will alternate on the display screen every 10 

seconds when in operation.
Once the ideal relative humidity has been 

reached, the mist release will stop operating 

automatically and will restart once the 

humidity level falls below the set humidity for 

the room temperature.

Summary of Contents for LAH508

Page 1: ...the Smart Mist TopTM Connect Humidifier Instruction Book LAH508...

Page 2: ...h 50ml h OS Compatibility Android 5 0 or later and iOS 9 0 or later NOTE Not compatible with Google Home Amazon Alexa or other similar voice assisted appliances IMPORTANT SAFEGUARDS READ ALL INSTRUCTI...

Page 3: ...ther surface that may be damaged by exposure to water or moisture It is recommended that a waterproof mat or pad is placed under the humidifier Do not operate the humidifier on a sink drain board Do n...

Page 4: ...et Before filling or emptying the water tank Before cleaningand maintenance unless otherwisespecifiedin thisbooklet Immediately after use Always use clean tap or distilled water to prevent clogging an...

Page 5: ...difier may become damp The humidifier is not intended to be operated by means of an external timer or separate remote control system or any other device that switches the humidifier on automatically D...

Page 6: ...experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that t...

Page 7: ...tently cause damage to the appliance and its electronic componentry Always turn the appliance to the off position switch off at the power outlet and unplug at the power outlet when the appliance is no...

Page 8: ...E Removable Water Tank F Control Panel G Body H Sensor I Non slip Feet J Remote Control K Water Buoy L Water Inlet Basin M Heating Plate N Transducer O Mood Light NOT PICTURED Aroma Tray Felt Pad Wate...

Page 9: ...rol Panel A Power On Off and Wi Fi B Humidity and Night Mode C Timer D Warm Ion and Mood Light E Mist Level Control Scroll left or right to change the mist level DISPLAY SCREEN ICONS ION Warm Mist Wat...

Page 10: ...el is considered to be between 40 60 RH Features Assembly BEFORE FIRST USE 1 Before using your humidifier for the first time remove all packaging material and promotional labels 2 Check for any missin...

Page 11: ...nsation will build on the top cover and around the humidifier 12 Connect the power plug to a 230V or 240V power outlet and switch the outlet on The POWER symbol will illuminate red and the WI FI icon...

Page 12: ...E HUMIDIFIER The humidifier comes with a memory feature When turned on from Standby mode it will start on the settings used previously The control panel lights will dim after approximately 30 seconds...

Page 13: ...display screen The RH number will flash 3 times then illuminate The FULL AUTO icon will illuminate and the icon will flash continuously during this setting The humidifier will start automatically if t...

Page 14: ...ht mode can be selected in all modes The Timer feature and Warm Mist feature can be used with this setting 1 Touch and hold the HUMIDITY NIGHT symbol on the control panel All the lights will turn off...

Page 15: ...bol again The ION icon will stop illuminating on the display screen Both WARM MIST and ION are now off AROMA TRAY Press the aroma tray on the side of the humidifier and it will click out of the unit A...

Page 16: ...e remote control point it at the display screen on the humidifier and used within five meters HINT When correctly inserted the text on the battery will be facing the bottom of the remote and the compa...

Page 17: ...e device is connected to a home Wi Fi network 2 The humidifier must be on standby mode Once the icon flashes rapidly on the display screen the humidifier is ready to connect 3 Log into your Breville H...

Page 18: ...control the humidifier using the Amazon Alexa or Google Home Assistant app the humidifier must be plugged in to an active power outlet and on standby mode VOICE CONTROL WITH AMAZON ALEXA Before you c...

Page 19: ...zer off NOTE Currently Amazon Alexa does not support the following settings Timer VOICE CONTROL WITH GOOGLE HOME ASSISTANT Before you can voice control your Breville Smart Mist Top Connect with Google...

Page 20: ...r off NOTE Currently Google Home Assistant does not support the following settings Timer TIPS for Amazon Alexa and Google Home Assistant Configure your Amazon Alexa or Google Home Assistant compatible...

Page 21: ...not use the humidifier unless it has been cleaned according to instructions TO CLEAN EXTERNAL PARTS Use a clean dry cloth to clean all external surfaces of the humidifier A soft slightly damp cloth m...

Page 22: ...THE PACKAGING FOR THESE CLEANING PRODUCTS Brush off any scale deposits from the transducer and heating plate surfaces using the brush or a cotton swab Rinse with clean or distilled water and allow to...

Page 23: ...to carefully lower the tank into the humidifier 8 Place the top cover on top of the water tank STORAGE Never store the humidifier with water in the unit Clean as per instructions and make sure that al...

Page 24: ...l the water tank and wait at least 1 minute The water level is low The water level required has not yet reached the vaporization compartment Wait at least 1 minute The water tank isn t positioned corr...

Page 25: ...water kept too long in the tank Clean water tank change to fresh clear water The ambient humidity is too high Humidifier is working in Manual mode Change the mode The humidity target is too high Sele...

Page 26: ...witch the unit off and contact the Breville Customer Service Centre White dust appears around the humidifier Water being used has a high mineral content Use distilled water with the humidifier If dist...

Page 27: ...r and there is no unwanted noise in the background While the voice assistant is always on in the background only an activation phrase will allow for the voice assistant to start registering the comman...

Page 28: ...logo Master Every Moment SensAir System Smart Mist Top and Breville Home Connect are trademarks of Breville Pty Ltd A B N 98 000 092 928 Copyright Breville Pty Ltd 2021 All other brands may be tradema...