background image

13

Troubleshooting

TROUBLE SHOOTING GUIDE

Before carrying out any of the following service checks, unplug the unit from the mains.

PROBLEM

POSSIBLE CAUSES

WHAT TO DO

Power indicator blue light 

is off or does not work.

• 

Humidifier is not plugged into 
the power outlet or the plug may 
be loose or the power outlet is 
not switched on.

• 

Check the power cord is connected to a 
power outlet and turned on, then press the 
power on button.

• 

No, or insufficient water in the 
tank.

• 

Fill the water tank.

The mist has a strange 

odour.

• 

When the humidifier is first 
used, there may be some residual 

odour that should dissipate.

• 

This is normal for first use. If the smell 
does not dissipate, check water quality 

as below.

• 

Water in the tank may be dirty or 
stagnant.

• 

Clean the water tank and refill with fresh, 
clean water.

• 

Mineral scale has built up in the 
water inlet basin.

• 

Clean as per instructions.

• 

Essential oil.

• 

If using the aroma feature, check that 
the essential oil used is not the cause of 
the odour and/or too much oil has been 
added.

Abnormal noise.

• 

Vibration in the water basin 
because the water level is too low.

• 

Fill the water tank with clean water.

The volume of the mist is 

too low.

• 

Mineral scale has built up in 
the water inlet basin and/or the 
nozzle.

• 

Clean as per instructions.

Mist is leaking out from 

area surrounding the 

mist nozzle.

• 

Mineral scale has built up in 
the water inlet basin and/or the 
nozzle.

• 

Clean as per instructions.

• 

The cover is not sitting correctly.

• 

Ensure the cover has been fitted correctly.

Mist is leaking from 

between the water tank 

and water base.

• 

Mineral scale has built up in the 

water inlet basin or the nozzle.

• 

Clean as per instructions.

• 

Water tank is not sitting correctly 
on base.

• 

Ensure water tank has been fitted on the 
base correctly.

Discolouration on the  

heating element.

• 

This is normal.

• 

The element should be cleaned regularly, 

however, discolouration that cannot be 
removed is normal with use.

Lights and beeps on 

the unit continue for a 

short time after being 

disconnected from power.

• 

This is normal.

• 

Residual energy will fade in a few 
seconds.

Summary of Contents for Easy Mist LAH300

Page 1: ...the Easy MistTM Humidifier Instruction Book LAH300...

Page 2: ...ny packaging material and promotional labels before using the humidifier for the first time To eliminate a choking hazard for young children remove and safely discard the protective cover fitted to th...

Page 3: ...cations Never place the humidifier where it may fall into a bath or other water container Do not use or store where it may get wet or in the immediate surroundings of a bath a shower or a swimming poo...

Page 4: ...me clean and dry the water tank before storage Clean the water tank every week Always disconnect the humidifier from the power supply and empty the water tank before moving Always carry the humidifier...

Page 5: ...NT SAFEGUARDS FOR ALL ELECTRICAL APPLIANCES Fully unwind the power cord before use Connect only to a 230V or 240V power outlet Do not let the power cord hang over the edge of a bench or table touch ho...

Page 6: ...should be disconnected from the power source at the wall socket to prevent any electrical surges that may arise during the storm and which may inadvertently cause damage to the appliance and its elec...

Page 7: ...r Level Window E Water Tank F Water Tank Cap G Aroma Tray H Air Outlet I Water Buoy J Cleaning Brush K Power Indicator Light L Water Inlet Basin M Heating Element N Transducer O Power Cord NOT PICTURE...

Page 8: ...8 MIST LEVEL POWER WARM MIST Control Panel A Power On Off B Mist Level C Warm Mist C A B...

Page 9: ...components list 3 Clean all parts according to the Care Cleaning Storage section 4 Place the humidifier on a flat surface that will not be damaged by exposure to water or moisture IMPORTANT It is rec...

Page 10: ...o increase to medium mist intensity There will be one beep and the mist level light will turn blue Press again to increase to high mist level intensity There will be one beep and the light will turn g...

Page 11: ...n on the surface of transducer will reduce the reliability of the unit WARM MIST This humidifier has a warm mist feature When selected a small internal heating element will heat the water to create a...

Page 12: ...o dry WATER INLET BASIN 1 The water inlet basin includes the water reservoir in the base of the unit that also houses the transducer and the heating element 2 Clean the water basin with a soft cloth I...

Page 13: ...essential oil used is not the cause of the odour and or too much oil has been added Abnormal noise Vibration in the water basin because the water level is too low Fill the water tank with clean water...

Page 14: ...14 NOTE...

Page 15: ...15...

Page 16: ...ville Customer Service Centre Breville the Breville logo Master Every Moment and Easy Mist are trademarks of Breville Pty Ltd A B N 98 000 092 928 Copyright Breville Pty Ltd 2019 Due to continued prod...