background image

Rev 06131 

 

Brehon Agrisystems Inc. is not responsible or liable for indirect, special, or consequential damages arising out of or in 
connection with the use or performance of the product or other damage with respect to any economic loss, loss of 
property, loss of revenue or profit, or costs of removal, installation, or reinstallation. 

 

INSTALLATION INSTRUCTIONS 

 
 

Connecting Power to Receiver: 

 
Using sufficiently heavy gage wire, (not included), c12vdc and Ground wires to the wire 
from the Electric Cylinder marked 

POWER IN

 

using the crimp connectors supplied. The 

polarity 

must

 be correct as follows: 

+12v

 on the 

BLUE

 wire

, and 

GROUND

 on the 

BROWN 

wire. Power may be supplied from the fused side of the ACCessories on the ignition 

switch so that the Receiver is only powered while the vehicle ignition key is on or alternatively, 
connected using an inline fuse directly to battery power. When the Power ON/Off switch on the 
bottom of the Receiver is turned on the Red LED indicator light should be ON indicating normal 
operation. 
 
 
 

Electric Cylinder Installation: 

 
Before mounting the Electric Cylinder on the end gate, determine the correct location for installing 
the mounting tabs by extending and retracting the cylinder to ensure required stroke. This can be 
accomplished once power is supplied to the Receiver by pressing the ENDGATE manual switches 
on the Receiver.  
 
Ensure the grain chute operates freely. Position the mounting tabs such that when the grain chute is 
fully open the cylinder is not quite fully retracted. Then check to ensure that the distance to fully 
close does not exceed the electric cylinder stroke length and that the electric cylinder can be 
mounted free of any obstacles. 
 
Weld or drill/bolt the mount tabs in position on the vertical center-line of the grain chute and box 
end panel at the desired positions.  
 
Attach the cylinder main body to the top mount tab using the bolt and locknut supplied. Attach the 
cylinder piston to the moveable grain chute with the snap pin supplied. Route the electrical wire 
and connect using the insulated crimp terminals supplied. Secure all wires using the cable ties 
provided.  
 

NOTE:

 The existing lift handle on the endgate need not be removed, however, it must not be able 

to lock in any position. This could cause the electric cylinder to stall resulting in reduced service 
life or destruction. 
 
 

Summary of Contents for G. Force

Page 1: ...ts encoded information to the Receiver which then decodes the information and performs the desired function When coupled with motor driver this system may be used to operate a swinging gate raise a ch...

Page 2: ...ed including interference that may cause undesired operation Specifications Transmitter Power 9 volt dc battery Frequency 418 MHz Modulation FM Indicators Power Transmit Red LED Case Size 2 6 x 4 1 x...

Page 3: ...ECL2S 12 Force 540 lb Speed 75 in sec Stroke 11 8 Full Stroke Closed Length 18 Pin to pin Electrical 9 5A 12v Full Load Duty Cycle 5 Hoist Driver Optional Force 40 in lb Torque max Speed 6 rpm no loa...

Page 4: ...or consequential damages arising out of or in connection with the use or performance of the product or other damage with respect to any economic loss loss of property loss of revenue or profit or cos...

Page 5: ...the Electric Cylinder on the end gate determine the correct location for installing the mounting tabs by extending and retracting the cylinder to ensure required stroke This can be accomplished once p...

Page 6: ...nnection with the use or performance of the product or other damage with respect to any economic loss loss of property loss of revenue or profit or costs of removal installation or reinstallation Vert...

Page 7: ...ect the existing flexible cable control from the valve arm and unbolt the cable from the reservoir bracket Select the appropriate hole to install the Hoist Driver Push Rod The distance from the center...

Page 8: ...of or in connection with the use or performance of the product or other damage with respect to any economic loss loss of property loss of revenue or profit or costs of removal installation or reinsta...

Page 9: ...itch settings will be able to talk to this Receiver When the switches are set identically and the transmitter talks to the Receiver the yellow RECEIVE light will come on This indicates that valid data...

Page 10: ...matically resetting fuses Fuse F1 1 Amp is intended to protect the RF receiver and data circuitry and Fuse F2 10 Amp is intended to protect the relays from overload These fuses will automatically rese...

Page 11: ...ruction of the Endgate Driver The Receiver power switch should be turned Off when not in use to prevent undesired operation HOIST DRIVER The G Force Hoist Driver shaft arm is designed to move each way...

Reviews: