10
BREEZY 90
Rev.F
ENGLISH
Options - Footplates
FOOTPLATES:
The footplates can be flipped up to make
it easier to transfer to/from the chair.
Each assembly weighs 1.0kg
LOWER LEG LENGTH:
For users with longer legs, the leg
support can be lowered to the
appropriate level by loosening the hand
wheel (1), pressing the spring button (2).
Push the tubes to the desired position.
The button will spring back into the
desired hole. Retighten the hand wheel.
There must always be a minimum gap of 2.5 cm between the footplates
and the ground, (Fig.9).
LEG RESTS AND LATCH
The leg rests can be swung outwards.
When fitting the leg rests, the leg rests
must be pointing outwards. Then rotate
the leg rest inwards, until it locks into
place. To remove, press the release
lever (1), swing the footplate outwards
and then lift the leg rest out. Make sure
that the leg rest is locked into place
correctly before use, (Fig.10).
CAUTION!
•
The legrests must not be used to lift or to carry the wheelchair.
•
When getting on or off the wheelchair, do not use the footboards.
These should be flipped up beforehand or the footrest should be
swung to the outside as far as possible.
FIG. 10
1
CASTORS, CASTOR PLATES, FORKS
The wheelchair may veer slightly to the right or left, or the castors
may wobble. This may be caused by the following:
• Forward and/or reverse wheel motion has not been set properly.
• The castor angle has not been set correctly.
• Castor and/or rear wheel air pressure is incorrect; the wheels do
not turn smoothly.
The wheelchair will not move in a straight line if the castors have
not been properly adjusted. Castors should always be adjusted by
an authorised dealer. The wheel locks must be checked every time
the rear wheel position has been altered.
The seat height is determined by the castor and rear wheel
position. The seat height can be adjusted by altering the position of
the rear wheels and the castors
CAUTION!
After adjusting the seat height, all screws must be re-tightened and
the wheel lock must be readjusted.
The castors must be set at 90
°
Options - Castors
Name Plate
NAMEPLATES
The nameplate is located on either the cross-tube assembly or the
transverse frame tube, as well as on a label in the owner’s manual.
The nameplate indicates the exact model designation and other
technical specifications. Please provide the following pieces of
information whenever you have to order replacement parts or to file
a claim:
FIG. 9
1
2
SAMPLE
Due to our policy of continuous improvement in the design of our
wheelchairs, product specifications may vary slightly from the
examples illustrated. All weight/dimensions and performance data
are approximate and provided solely for guidance.
Sunrise Medical complies with the EU Medical Devices Regulation
(EU) 2017/745.
All wheelchairs must be used in accordance with the
manufacturer’s guidelines.
Sunrise Medical
Thorns Road
Brierley Hill
West Midlands
DY5 2LD
Phone: 0845 605 66 88
Fax:
0845 605 66 89
www.SunriseMedical.co.uk
ENGLISH
208210122050
22.01.2021
42cm
125kg
Breezy 90
Type:
40cm
Breezy 90
Product Name/SKU Number.
XXXX-XX-XX
ISO 7176-19:2008
Maximum safe slope with anti-tip tubes fitted,
Depends on wheelchair setting, posture and
physical capabilities of the user.
CE Mark.
User’s Guide.
Date of manufacture.
Serial number.
This symbol means Medical Device.
Manufacturer’s address.
Crash tested according to
ISO 7176-19:2008.
XXX mm
Seat depth.
Seat width.
XXX mm
Load Maximum.
XXX kg
kg
max X°