Breeze33 BZ3310WAC1 User Manual Download Page 4

Do not, under any
circumstances, cut,
remove, or bypass
the grounding prong.

Power supply cord
with 3-prong grounding plug
and current detection device

Grounding type wall
receptacle

WARNING

NOTE:

The power supply cord with this air 
conditioner contains a current detection 
device designed to reduce the risk of fire.

 

Please refer to the section Operation

 

of 

Current Device for details.

 

In the event 

that the power supply cord is damaged, 
it cannot be repaired-it must be replaced 
with

 a cord from the Product Manufacturer.

Avoid fire hazard or electric shock. Do not
use an extension cord or an adaptor plug. 
Do not remove any prong from the power 
cord. 

WARNING

For Your Safety

WARNING

Prevent Accidents

WARNING

Electrical Information

Do not store or use gasoline or other flammable vapors and liquids in the vicinity  
of this or any other appliance.

Operation of Current Device

(Applicable to the unit adopts current detection 
device only )

The power supply cord contains a current device that senses 
damage to the power cord. To test your power supply cord do 
the following:
1. Plug in the Air Conditioner.
2. The power supply cord will have TWO buttons on the plug

head. Press the TEST button, you will notice a click as the
RESET button pops out.

3. Press the RESET button, again you will notice a click as

the button engages.

4. The power supply cord is now supplying electricity to the

unit. (On some products this it also indicated by a light on
the plug head.)

3

To reduce the risk of fire, electrical shock, or injury to persons when using your
air conditioner, follow basic precautions, including the following:
    Be sure the electrical service is adequate for the model you have chosen. This

 

    information can be found on the serial plate, which is located on the side of the

 

    the cabinet and behind the grille.
    If the air conditioner

 

is

 

t o

 

b e

 

installed in a window, you

 

w ill

 

pr obably

 

w ant

 

to cl ean

 

   

    

both sides of the glass

 

f irst.

  If the window is 

a tri ple-track

 

ty pe

 

w ith

 

a sc reen

 

   panel 

included, remove the screen completely before installation.

    Be sure the air conditioner

 

h as

 

b een

 

s ecurely

 

a nd

 

c orrectly

 

in stalled

 

a ccording

 

to  

  

    

the installation instructions in this manual. Save this manual for possible future

 

   

    

use in removing or installing this unit.

    When handling the air conditioner, be careful to avoid cuts

 

f rom sharp metal

 

f ins

 

    on front and rear coils. 

The complete electical rating of your new room air conditioner is stated on the 
serial plate. Refer to the rating when checking the electrical requirements.
     Be sure the air conditioner is properly grounded. To minimize shock and fire 
     hazards, proper grounding is important. The power cord is equipped with a 
     three-prong grounding plug for protection against shock hazards.
     Your air conditioner must be used in a properly grounded wall receptacle. If the 
     wall receptacle you intend to use is not adequately grounded or protected by a 
     time delay fuse or circuit breaker, have a qualified electrician install the proper 
     receptacle. Ensure the receptacle is accessible after the unit installation.
     Do not run air conditioner without side protective cover in place.This could 
     result in mechanical damage within the air conditioner.
     

Do not use an extension cord or an adapter plug.

IMPORTANT SAFETY INSTRUCTIONS

    Do not use this device to turn the unit on or off.
    Always make sure the RESET button is pushed in for 
    correct operation.
    The power supply must be replaced if it fails reset when 
    either the TEST button is pushed, or it cannot be reset. A 
    new one can be obtained from the product manufacturer.
    If power supply cord is damaged, it cannot be repaired. It 
    MUST be replaced by one obtained from the product 
    manufacturer. 

NOTE:

NOTE:

This air conditioner is designed to be operated 

            under condition as follows:

Cooling 
operation

Outdoor temp: 

Indoor temp: 

Heating 
operation

Outdoor temp: 

O

O

23-76 F/-5-24 C

Indoor temp: 

O

O

32-80 F/0-27 C

O

O

O

O

64-109 F/18-43 C (64-125 F/18-52 C
for special tropical models)

O

O

62-90 F/17-32 C

Note: Performance may be reduced outside of these 
operating temperatures.

Summary of Contents for BZ3310WAC1

Page 1: ...ITIONER Before using your air conditioner please read this manual carefully and keep it for future reference WINDOW TYPE ROOM AIR CONDITIONER Before using your air conditioner please read this manual...

Page 2: ...excess heat generation It may cause electric shock or fire due to heat generation Incorrect grounding may cause electric shock It may cause fire and electric shock It may cause fire It may cause explo...

Page 3: ...ters maycause failure It contains contaminants and could make you sick Stop operation and close the window in storm or hurricane Do not use strong detergent such as wax or thinner but use a soft cloth...

Page 4: ...e window is a triple track type with a screen panel included remove the screen completely before installation Be sure the air conditioner has been securely and correctly installed according to the ins...

Page 5: ...ance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants DO NOT modify the length of...

Page 6: ...Checks to the area Prior to beginning work on systems containing flammable refrigerants safety checks are necessary to ensure that the risk of ignition is minimized For repair to the refrigerating sys...

Page 7: ...sence of refrigerant Marking to the equipment continues to be visible and legible Markings and signs that are illegible shall be corrected Refrigeration pipe or components are installed in a position...

Page 8: ...detection of refrigerant leaks A halide torch or any other detector using a naked flame shall not be used 11 Leak detection methods The following leak detection methods are deemed acceptable for syste...

Page 9: ...system shall be leak tested on completion of charging but prior to commissioning A follow up leak test shall be carried out prior to leaving the site 14 Decommissioning Before carrying out this proced...

Page 10: ...recovery occurs The recovery equipment shall be in good working order with a set of instructions concerning the equipment that is at hand and shall be suitable for the recovery of flammable refrigera...

Page 11: ...trations in this manual are for explanation purposes only The air conditioner you have may be slightly different NOTE 4 INSTALLATION INSTRUCTIONS NOTE The unit you purchased may be look like one of th...

Page 12: ...in these instructions when installing this air conditioner BEFORE YOU BEGIN Do not under any circumstances cut or remove the third ground prong from the power cord CAUTION Do not change the plug on t...

Page 13: ...tu h models only Fig C NOTE The top rail hardware and the Fig A Fig B and Fig C are not applicable to the units more than 10000Btu h Before installing unit the top rail must be assembled on the unit F...

Page 14: ...against the window sill Fig 5A and Fig 5B Carefully close the window behind the top rail of the unit Fig 5A NOTE If storm window blocks AC see Fig 11 Top Rail Bottom Rail Top left Top right Fig 4 Woo...

Page 15: ...s through the holes in the frame lock and frame extensions into the windows sash as shown Fig 8B Fig 8A Fig 8B C To secure lower sash in place attach right angle sash lock with 3 4 19mm or 1 screw as...

Page 16: ...rm grip on air conditioner raise sash and carefully remove Be carefully not to spill any remaining water while lifting unit from window Store parts WITH air conditioner Board thickness as required for...

Page 17: ...coils Save Carton and these Installation Instructions for future reference The carton is the best way to store unit during winter or when not in use NOTE Preliminary Instructions Do the following befo...

Page 18: ...inch Long Flat Head Bolt and Locknut Sill Angle Bracket Long hex head locking screw for top angle side retainer 5 16 inch Long 2 ea 7 1 4ea 2ea 2 10 Foam insert 2 Window sash seal foam 1 A Window Moun...

Page 19: ...t totally tigh ten Allow leg to slide freely Screws will be tightened after section 6 4 Place Cabinet in window 1 Open window and mark center of window inner sill as shown Fig 11 2 Place cabinet in wi...

Page 20: ...cking screws Loosen screws so filler panels slide easily 2 Extend panels to fill window opening completely Tighten locking screws on top Fig 17 3 Install support brackets with sill angle brackets atta...

Page 21: ...gh the hole in the top leg of each window filler panel and into the window sash Fig 18A and Fig 18B Connect with one 3 4 or 1 2 long hex head screw 8 1 Trim sash seal to fit window width Insert into s...

Page 22: ...plicable to Energy Star models In order to minimize air leaks and ensure optimal insulation it is necessary to install the included R1 hardware to the side curtain Follow the instructions below Step 1...

Page 23: ...ion are provided except a wood frame shims and 10 wood screws 10 1 long minimum Select a wall surface that 1 does not support major structural loads such as the frame construction at ends of windows a...

Page 24: ...d to eliminate distortion See Fig 8 Remember to maintain proper slope as described in Step 3 Fig 8 OPTIONAL Caulking and installation of trim on interior wall may be done You can buy wood from your lo...

Page 25: ...he cooling cycle Gurgle Hiss Gurgling or hissing noise may be heard due to refrigerant passing through evaporator during normal operation Pinging or Switching Droplets of water hitting condenser durin...

Page 26: ...ctional Louvers Lever Air Direction The louvers will allow you to direct the air flow Left or Right throughout the room as needed Move the Levers from side to side until the desired Left Right directi...

Page 27: ...gher cool settings will provide lower room temperature Rotate the thermostat selector counter clockwise for lower cool settings Lower cool settings will provide higher room temperature Cool Mode The d...

Page 28: ...Auto Med High TEMP TIMER Auto Cool Dry Fan Fan Mode On Off Sleep Timer Check Filter Energy Saver Follow Me Ion Temp Temp Timer Timer On Off Sleep Check Filter Timer Auto Cool Dry Fan Low Auto Med High...

Page 29: ...t the remote control towards the unit and press the Follow Me button T If the unit does not receive the Follow Me signal during any 7 minutes interval the unit will beep to indicate the Follow Me mode...

Page 30: ...w Be sure to unplug the unit before cleaning to prevent shock or fire hazards Air Filter Cleaning The air filter should be checked at least once a month to see if cleaning is necessary Trapped particl...

Page 31: ...cted Push plug firmly into wall outlet House fuse blown or circuit breaker tripped Replace fuse with time delay type or reset circuit breaker Plug Current Device Tripped Press the RESET button Problem...

Page 32: ...stricted Clean air filter Air movement sound This is normal If too loud set to a slower FAN setting Outside temperature extremely hot Set FAN speed to a Higher setting to bring air past cooling coils...

Reviews: