Breeze33 BZ3310WAC1 User Manual Download Page 18

17

Locking screw   10X 1/ 4 panhead Phillips
screws (for Vinyl-Clad window)(on some models) 

INSTALLATION  INSTRUCTIONS

3.

Check your storm  windows

-- if your storm

window frame does not allow the clearance
required, correct by adding a piece of wood as
shown in Fig.E,or by removing storm window
while room air conditioner is being installed.

   4 .

Check for anything that could block airflow

--

       check area outside of window for things such as
       shrubs, trees, or awnings. Inside, be sure 
       furniture, drapes, or blinds will not stop proper 
       airflow.

5.

Check the available electrical service-

 Power

supply must be the same as that shown on the
unit serial nameplate. Power cord is 48 inches
long. Be sure you have an outlet near.

6.

Carefully unpack air conditioner-

 Remove all

packing material. Protect floor or carpet from
damage. Two people should be used to move
and install unit.

Preliminary Instructions

Tools Required

A large flat blade screwdriver; Tape measure;
Adjustable wrench or pliers; Pencil; Level
Socket wrenches; Phillips Screwdriver

Hardware(Packed with the unit)

7/16 inch Locking screw and 
Flat washer for window panels

3 / 4 

or 1/2)inch Long 

Hex-head Screw

Safety Lock

1 / 2 inch Long screw and Locknut 

3 / 4 inch Long Flat Head 

Bolt and Locknut

Sill Angle Bracket

Long hex-head locking 
screw for top angle, side 
retainer 5 /16 inch Long

2 ea.

7

1

4ea.

2ea.

2

10

Foam insert

2

Window sash 
  seal foam 

1

A.Window Mounting

1

Remove Air Conditioner from Cabinet

1.Pull down front grille and remove filter.

(See Fig.1).

2.Lift front grille upwards and place to one side.
3.Locate the four front screws and remove.

These screws will be needed to re-install

the front panel (see Fig.2).

7. Remove shipping screws from top of unit and

also on the side by the base if installed
(see Fig.5).

8. Hold the cabinet while pulling on the base pan

handle, and carefully remove the unit.

9. Add two foam inserts to holes in top of cabinet

where shipping screws were removed from
(see Fig.6).

4.Push metal cabinet side to release plastic tabs

on each side of front panel (see Fig.3).

5.Gently lift front panel off unit(see Fig.3A).
6.Disconnect the connector plug of the display

panel from the unit and place front panel to one
side(see Fig.4).

Front Grille

Fig.1

Fig.2

Fig.3

Fig.3A

Front Panel

Fig.4

shipping
screws

Fig.5

Fig.6

R1 hardware

2

(10 *3/4 *1/12 )
     

NOET: R1 hardware and Weather stripping is only 
for Energy star models.

Weather stripping

5

NOTE: Remove any packaging material from 
cabinet exterior.

Safety Lock

(for Vinyl-Clad window)(on some models)

2

2

Lock Frame

(For Wooden 

windows)(on some models)

        

2

3 / 4 inch Long Screw(on some models)

2

Summary of Contents for BZ3310WAC1

Page 1: ...ITIONER Before using your air conditioner please read this manual carefully and keep it for future reference WINDOW TYPE ROOM AIR CONDITIONER Before using your air conditioner please read this manual...

Page 2: ...excess heat generation It may cause electric shock or fire due to heat generation Incorrect grounding may cause electric shock It may cause fire and electric shock It may cause fire It may cause explo...

Page 3: ...ters maycause failure It contains contaminants and could make you sick Stop operation and close the window in storm or hurricane Do not use strong detergent such as wax or thinner but use a soft cloth...

Page 4: ...e window is a triple track type with a screen panel included remove the screen completely before installation Be sure the air conditioner has been securely and correctly installed according to the ins...

Page 5: ...ance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants DO NOT modify the length of...

Page 6: ...Checks to the area Prior to beginning work on systems containing flammable refrigerants safety checks are necessary to ensure that the risk of ignition is minimized For repair to the refrigerating sys...

Page 7: ...sence of refrigerant Marking to the equipment continues to be visible and legible Markings and signs that are illegible shall be corrected Refrigeration pipe or components are installed in a position...

Page 8: ...detection of refrigerant leaks A halide torch or any other detector using a naked flame shall not be used 11 Leak detection methods The following leak detection methods are deemed acceptable for syste...

Page 9: ...system shall be leak tested on completion of charging but prior to commissioning A follow up leak test shall be carried out prior to leaving the site 14 Decommissioning Before carrying out this proced...

Page 10: ...recovery occurs The recovery equipment shall be in good working order with a set of instructions concerning the equipment that is at hand and shall be suitable for the recovery of flammable refrigera...

Page 11: ...trations in this manual are for explanation purposes only The air conditioner you have may be slightly different NOTE 4 INSTALLATION INSTRUCTIONS NOTE The unit you purchased may be look like one of th...

Page 12: ...in these instructions when installing this air conditioner BEFORE YOU BEGIN Do not under any circumstances cut or remove the third ground prong from the power cord CAUTION Do not change the plug on t...

Page 13: ...tu h models only Fig C NOTE The top rail hardware and the Fig A Fig B and Fig C are not applicable to the units more than 10000Btu h Before installing unit the top rail must be assembled on the unit F...

Page 14: ...against the window sill Fig 5A and Fig 5B Carefully close the window behind the top rail of the unit Fig 5A NOTE If storm window blocks AC see Fig 11 Top Rail Bottom Rail Top left Top right Fig 4 Woo...

Page 15: ...s through the holes in the frame lock and frame extensions into the windows sash as shown Fig 8B Fig 8A Fig 8B C To secure lower sash in place attach right angle sash lock with 3 4 19mm or 1 screw as...

Page 16: ...rm grip on air conditioner raise sash and carefully remove Be carefully not to spill any remaining water while lifting unit from window Store parts WITH air conditioner Board thickness as required for...

Page 17: ...coils Save Carton and these Installation Instructions for future reference The carton is the best way to store unit during winter or when not in use NOTE Preliminary Instructions Do the following befo...

Page 18: ...inch Long Flat Head Bolt and Locknut Sill Angle Bracket Long hex head locking screw for top angle side retainer 5 16 inch Long 2 ea 7 1 4ea 2ea 2 10 Foam insert 2 Window sash seal foam 1 A Window Moun...

Page 19: ...t totally tigh ten Allow leg to slide freely Screws will be tightened after section 6 4 Place Cabinet in window 1 Open window and mark center of window inner sill as shown Fig 11 2 Place cabinet in wi...

Page 20: ...cking screws Loosen screws so filler panels slide easily 2 Extend panels to fill window opening completely Tighten locking screws on top Fig 17 3 Install support brackets with sill angle brackets atta...

Page 21: ...gh the hole in the top leg of each window filler panel and into the window sash Fig 18A and Fig 18B Connect with one 3 4 or 1 2 long hex head screw 8 1 Trim sash seal to fit window width Insert into s...

Page 22: ...plicable to Energy Star models In order to minimize air leaks and ensure optimal insulation it is necessary to install the included R1 hardware to the side curtain Follow the instructions below Step 1...

Page 23: ...ion are provided except a wood frame shims and 10 wood screws 10 1 long minimum Select a wall surface that 1 does not support major structural loads such as the frame construction at ends of windows a...

Page 24: ...d to eliminate distortion See Fig 8 Remember to maintain proper slope as described in Step 3 Fig 8 OPTIONAL Caulking and installation of trim on interior wall may be done You can buy wood from your lo...

Page 25: ...he cooling cycle Gurgle Hiss Gurgling or hissing noise may be heard due to refrigerant passing through evaporator during normal operation Pinging or Switching Droplets of water hitting condenser durin...

Page 26: ...ctional Louvers Lever Air Direction The louvers will allow you to direct the air flow Left or Right throughout the room as needed Move the Levers from side to side until the desired Left Right directi...

Page 27: ...gher cool settings will provide lower room temperature Rotate the thermostat selector counter clockwise for lower cool settings Lower cool settings will provide higher room temperature Cool Mode The d...

Page 28: ...Auto Med High TEMP TIMER Auto Cool Dry Fan Fan Mode On Off Sleep Timer Check Filter Energy Saver Follow Me Ion Temp Temp Timer Timer On Off Sleep Check Filter Timer Auto Cool Dry Fan Low Auto Med High...

Page 29: ...t the remote control towards the unit and press the Follow Me button T If the unit does not receive the Follow Me signal during any 7 minutes interval the unit will beep to indicate the Follow Me mode...

Page 30: ...w Be sure to unplug the unit before cleaning to prevent shock or fire hazards Air Filter Cleaning The air filter should be checked at least once a month to see if cleaning is necessary Trapped particl...

Page 31: ...cted Push plug firmly into wall outlet House fuse blown or circuit breaker tripped Replace fuse with time delay type or reset circuit breaker Plug Current Device Tripped Press the RESET button Problem...

Page 32: ...stricted Clean air filter Air movement sound This is normal If too loud set to a slower FAN setting Outside temperature extremely hot Set FAN speed to a Higher setting to bring air past cooling coils...