SPECIFICATIONS
FREESTANDING:
Width: 26”
Height: 33 ¼”
Depth: 30 7/8” (excluding ash lip)
Weight: 325 lbs.
Flue size: 3” or 4”
Hopper Capacity: Up to 65 lbs.
(this can vary widely depending on pellet size, length, and diameter)
EPA status: exempt
Burn time: 1 lb. to 5 lbs. per hour
BTU range: 8,200 to 50,000
Approved installations: mobile home, alcove, conventional
FIREPLACE INSERT:
Width: 22” (at fireplace rear)
29 ½” (at fireplace opening)
Height: 21” (in fireplace)
Depth: 23 ½” (total)
16 3/8” (in fireplace)
Flashing Size: 44 ½” W x 28” H (medium)
48 ½” W x 32” H (large)
Weight: 250 lbs.
Flashing: 13 lbs.
Flue size: 3” or 4”
Hopper Capacity: Up to 70 lbs.
(this can vary widely depending on pellet size, length, and diameter)
EPA status: exempt
Burn time: 1 lb. to 5 lbs. per hour
BTU range: 8,200 to 50,000
Approved installations: zero-clearance, masonry, as a built-in
PREPARATION
Factory packaging must be removed, and some minor assembly work is required
prior to installation. Access to the rear of the stove is necessary.
The circuit board/control panel must be unpacked and installed in the side
flashing on the insert. (See installation instructions provided with the circuit
board)
NOTE: Normally, your dealer will perform these functions.
CLEARANCES
The Breckwell P24 Freestanding has been tested and listed for installation in
residential, mobile home and alcove applications.
The P24 Insert is approved for installation into code complying masonry
fireplaces.
The P24 Insert is also approved for use in listed factory built fireplaces (UL 127)
and standard residential built-ins (see
As A Built-In Fireplace
), including Mobile
Home built-in installations, of the following description: all brands at least 36”
wide and 20” high.
FLOOR PROTECTION: Freestanding installations, minimum 25” wide by 35”
deep. The stove must be placed on a continuous (grouted joints)
noncombustible material such as ceramic tile, cement board, brick, 3/8”
millboard or equivalent, or other approved or listed material suited for floor
protection.
THE MATERIAL(S) USED MUST HAVE, OR COMBINE TO HAVE, A MINIMUM
INSULATIVE RATING OF ‘R1’.
NOTE: ceramic tile, or any tile, requires a continuous sheet beneath to prevent
the possibility of embers falling through to the combustible floor if cracks or
separation should occur in the finished surface, this would include floor
protection for Built-in raised hearths. Check local codes for approved
alternatives.
Clearances are measured from the sides, back and face (door opening) or stove
body (refer to fig. 4).
DO NOT USE MAKESHIFT MATERIALS OR COMPROMISES IN THE
INSTALLATION OF THIS UNIT.
INSTALL VENT WITH CLEARANCES SPECIFIED BY THE VENT
MANUFACTURER.
INSTALLATION
5
SIDEWALL CLEARANCES
FIGURE 1
ALCOVE CLEARANCES
FIGURE 2
FIGURE 3
FLOOR PROTECTION
FIGURE 4