PARTS DIAGRAM AND LIST

Key

Description

Part #

Qty

1

Feed Door Assy. (w/Rope Gasket)

69679

1

2

Door Handle

24179

2

N/S

Lock Nut, 1/2-13

83444

2

N/S

Washer

83835

2

3

Spring Handle

891135

4

4

Feed Door Latch

23786

1

5

Ash Door Assy. (w/Rope Gasket)

68880

1

6

Draft Cap

23859

1

7

Ash Door Latch

23823

1

N/S

Hinge Pin, 5/16” x 1”

C21399

4

8

Shaker Handle

69005

1

9

Bracket, Shaker Handle

24204

1

10

Ash Pan

68882

1

11

Grate Retainer

40312

2

12

Shaker Bar

891341

1

13

Shaker Grate Section

40314

5

14

Back Liner

40313

1

15

Front Liner

40344

1

16

Full Firebrick (4-1/2 wide x 9 tall x 1-1/4 thick)

89066

16

17

Half Firebrick (2-1/4 wide x 9 tall x 1-1/4 thick)

891414

3

18

Slide Baffle

24231

1

19

Baffle Rod

86603

1

20

Lock Nut, 1/2-13

83444

2

21

Gasket, Flue Collar

88032

1

22

Flue Collar

40246

1

23

Flue Collar Ring

22761

1

24

Smoke Curtain

23800

1

25

Smoke Door Clip

23787

2

26

Carriage Bolt, 1/4-20 x 1-1/4 Long

83445

2

27

Kep Nut, 1/4-20

83250

2

28

Cabinet Side, Left

69676B

1

29

Insulation, Side

C98771

2

30

Insulation Retainer

83884

41

31

Cabinet Side, Right

69675B

1

32

Receptacle, Snap-In

80351

1

33

Cabinet Back

69573B

1

34

Insulation, Panel

C98871

2

35

Cabinet Top

69088B

1

36

Front Filler

69674B

1

37

Draft Cover

23818B

1

38

Room Blower - 800 CFM

80530

2

1

4

3

5

2

Key

Description

Part #

Qty

1

Drqft Blower Assembly

69190

1

2

FAD Bracket

69192

1

3

Bolt, 1/4-20 x 1”

83379

2

4

Lock Nut, 1/4-20

83261

2

5

Kep Nut, 10-24

83244

3

Key

Description

Part #

Qty

39

Blower Gasket

88127

2

40

Tinnerman Clip, 1/4-20

83340

8

41

Bolt, 1/4-20 x 3/4

83339

8

42

Conduit Assembly (5ft)

69578

2

43

Honeywell Limit Control

80145

1

44

Conduit Assembly (1ft)

68859

1

45

Junction Box

25625

1

46

Insulation (5” x 5”)

25626

1

47

Rocker Switch

C42373

1

48

Romex Cable Clamp

80362

1

49

Fan Center Control

80130

1

50

Water Coil Access Cover

23819

1

Summary of Contents for SF747

Page 1: ...ce is not properly installed a house fire may result For your safety follow these installation instructions Contact local building or fire officials about restrictions and installation requirements in...

Page 2: ...2...

Page 3: ...se qAlternative Heat qMain Heat Source qDecoration qCost qOther _________________________ What was the determining factor for purchasing your new appliance _____________ I have read the owner s manual...

Page 4: ...4 Fold Here Fold Here United States Stove Company P O Box 151 South Pittsburg TN 37380 Fold Here PLACE STAMP HERE CUT HERE CUT HERE...

Page 5: ...ent and the chim ney to which the unit is attached The actual area that this unit will heat depends on factors such as the conditions of the building heat loss type of construction amount of insulatio...

Page 6: ...r bird screen should be in stalled on top of the chimney CREOSOTE FORMATION AND NEED FOR REMOVAL When wood is burned slowly it produces tar and other organic vapors which combine with expelled moistur...

Page 7: ...should never be reduced to a smaller size than flue opening on the furnace 5 The connector pipe should not block the flue of the chimney or extend into it in any way 6 A good airtight thimble should...

Page 8: ...er furnace per formance Failure to provide return air ducts of the specified size will void your warranty A filter should be installed in the cold air return Furnace filters should be checked and clea...

Page 9: ...ackets on the left side of the door frames as il lustrated The slots in the brackets and latches are for door seal adjust ment Make the proper adjustments then tighten the nuts The door s gasket shoul...

Page 10: ...ack The conduit as sembly should already be attached to the limit control otherwise do so then make the correct wiring connections to the limit control See wiring diagram 4 Next mount the junction box...

Page 11: ...he furnace Then mount and secure the draft blower to the adapter with the three 10 24 Kep nuts Plug the blower into the outlet on the front of the furnace 1 Draft Blower 1 Draft Blower Adapter 2 1 4 2...

Page 12: ...In normal shaking only rock the grates a small amount to sift ash through Do not agitate the fire bed too often This practice will waste coal If glowing coal is visible in the ash pan you have shaken...

Page 13: ...not recommended burning the furnace any more than necessary early in the fall and late spring as you cannot keep the firebox hot enough without overheating your home to burn gases Slow fires can cause...

Page 14: ...C Makesurechimneycapisnottooclosetothetopofthechimney D Check chimney draft make sure chimney flue pipe is clean and chimney is of adequate height E Makesureyou renotsuffocatingthefirewithexcessiveam...

Page 15: ...15 PARTS DIAGRAM 11 12 13 16 15 17 14 7 10 5 2 3 6 32 31 4 3 2 1 37 3 8 9 24 26 25 27 17 16 3 19 18 20 28 29 30 36 21 22 34 34 35 23 33...

Page 16: ...ng 22761 1 24 Smoke Curtain 23800 1 25 Smoke Door Clip 23787 2 26 Carriage Bolt 1 4 20 x 1 1 4 Long 83445 2 27 Kep Nut 1 4 20 83250 2 28 Cabinet Side Left 69676B 1 29 Insulation Side C98771 2 30 Insul...

Page 17: ...he coil with the appropriate fittings As mentioned earlier in this manual a cold air return and or filter box should be incorporated into your furnace installation A cold air re turn or filter box wil...

Page 18: ...cy There will have to be some experimenting with the individual setup as no two chimney s or installations are going to be the same Just remember to allow enough air to enter the firebox and keep the...

Page 19: ...llow the same procedure as for refueling If possible avoid shaking as a heavier layer of ash will help reduce the intensity of the fire during this time After loading let the fire establish itself for...

Page 20: ...ure reference When placing an order or for warranty claims please provide the following information found on the Certification Plate located below the ash door PART NUMBER PART DESCRIPTION MODEL NUMBE...

Reviews: