Breckwell ECO-AIRE SP8000 Owner'S Operation And Instruction Manual Download Page 2

2

 

Ussc

 

IMPORTANT:

    Read  this  entire  manual  before 

installing and operating this product.  Failure to do 

so may result in property damage, bodily injury, 

or even death.  Proper installation of this heater is 

crucial for safe and efficient operation. Never use 

make-shift compromises during the installation.

 

Before  installing  your  heater,  you  must  perform 

an initial burn in an OUTSIDE environment. Follow 

the Start-Up Procedure in the Operation section 

of this manual.

 

This heater must be installed in an exterior wall or 

window to the outside.

 

Contact  your  local  building  officials  to  obtain 

a  permit  and  information  on  any  additional 

installation restrictions or inspection requirements 

in your area.

 

Save these instructions..  This manual has important 

operating  and  maintenance  instructions  that 

you will need at a later time.  Always follow the 

instructions in this manual.

 

This heater is designed and approved for premium 

hardwood pellet fuel only.  Any other type of fuel 

burned in this heater will void the warranty and 

safety listing.

 

Never  use  gasoline,  gasoline-type  lantern 

fuel,  kerosene,  charcoal  lighter  fluid,  or  similar 

flammable liquids to start or “freshen up” a fire in 

this heater.  Keep all such liquids well away from 

the heater while it is in use.

 

A working smoke detector must be installed in the 

same room as this product.

 

Do  not  unplug  the  heater  if  you  suspect  a 

malfunction.  Turn the ON/OFF SWITCH to ”OFF’ 

and contact your dealer.

 

Do not operate your heater with the viewing or 

combustion door open.  The auger will not feed 

pellets under these circumstances and a safety 

concern may arise from sparks or fumes entering 

the room.

 

Never disable or bypass the safety devices in this 

unit. Doing so could result in damage to the unit 

or endanger yourself or someone else. 

 

Your  heater  requires  periodic  maintenance 

and cleaning (see ”MAINTENANCE ”). Failure to 

maintain your heater may lead to improper and/

or unsafe operation.

 

Never  try  to  repair  or  replace  any  part  of  the 

heater unless instructions for doing so are given 

in this manual.  All other work should be done by 

a trained technician.

 

Turn the heater OFF and allow to completely cool 

before performing any maintenance.

Safety Precautions

 

Disconnect the power cord before performing any 

maintenance!  NOTE: Turning the ON/OFF Switch 

to  ”OFF”  does  not  disconnect  all  power  to  the 

electrical components of the heater.

 

Ashes must be disposed in a metal container with 

a tight fitting lid.  The closed container of ashes 

should be placed on a non-combustible surface 

or on the ground, well away from all combustible 

materials, pending final disposal.

 

The exhaust system should be checked bi- monthly 

during  the  burning  season  for  any  build-up  of 

flyash, soot or creosote. 

 

HOT  WHILE  IN  OPERATION.  KEEP  CHILDREN 

CLOTHING AND FURNITURE AWAY. CONTACT MAY 

CAUSE SKIN BURNS. Do not touch the hot surfaces 

of the heater.  Educate all children on the dangers 

of  a  high-temperature  heater.  Young  children 

should be supervised when they are in the same 

room as the heater.

 

A power surge protector is required.  This unit must 

be  plugged  into  a  110  -  120V,  60  Hz  grounded 

electrical  outlet.  Do  not  use  an  adapter  plug 

or  sever  the  grounding  plug.  Do  not  route  the 

electrical cord over the heater.  Do not route the 

cord in foot traffic areas or pinch the cord under 

furniture.

 

The  heater  will  not  operate  during  a  power 

outage. If a power outage does occur, check the 

heater for smoke spillage and open a window if 

any smoke spills into the room.

 

Never block free airflow through the open vents 

of the unit.

 

Keep foreign objects out of the hopper.

 

The moving parts of this heater are propelled by 

high torque electric motors.  Keep all body parts 

away from the auger while the heater is plugged 

into an electrical outlet.  These moving parts may 

begin  to  move  at  any  time  while  the  heater  is 

plugged in.

 

Do not place clothing or other flammable items 

on or near this heater. 

 

WARNING—DO  NOT  INSTALL  THIS  UNIT  IN  A 

SLEEPING  ROOM.    CAUTION—THE  STRUCTURAL 

INTEGRITY  OF  THE  MOBILE  HOME  FLOOR,  WALL, 

AND CEILING/ROOF MUST BE MAINTAINED.

 

This appliance is not intended for commercial use.

 

DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST 

VENTING SYSTEM OF THIS UNIT.

 

DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE 

SERVING ANOTHER APPLIANCE.

 

DO NOT USE CHEMICALS OR FLUIDS TO START THE 

FIRE;  DO  NOT  BURN  GARBAGE  OR  FLAMMABLE 

FLUIDS SUCH AS GASOLINE, NAPHTHA OR ENGINE 

OIL.

Summary of Contents for ECO-AIRE SP8000

Page 1: ...ully Before Starting The Installation or Operating This Heater ImproperInstallationCouldVoid Your Warranty SAFETY TESTED TO ASTM 1509 04 ULC S 627 00 227 Industrial Park Road P O Box 151 South Pittsbu...

Page 2: ...echnician Turn the heater OFF and allow to completely cool before performing any maintenance Safety Precautions Disconnect the power cord before performing any maintenance NOTE Turning the ON OFF Swit...

Page 3: ...Reason for Purchase qAlternative Heat qMain Heat Source qDecoration qCost qOther_________________________ What was the determining factor for purchasing your new USSC appliance _______ I have read th...

Page 4: ...4 Ussc CUT HERE CUT HERE Fold Here Fold Here United States Stove Company P O Box 151 South Pittsburg TN 37380 Fold Here Place Stamp Here...

Page 5: ...ee of insulation and the outside temperature 3 Pellet size may effect the actual rate of fuel feed and burn times Fuel feed rates may vary by as much as 20 Use PFI listed fuel for best results Electri...

Page 6: ...n of a heater due to improper venting or installation Call 800 750 2723 and or consult a professional installer if you have any questions INSTALL VENT AT CLEARANCES SPECIFIED ABOVE Your Eco Aire heate...

Page 7: ...nches 1 5M General Installation Clearance This unit is approved for Zero Clearance to any installed combustible surface such as the window sash sill or wooden structure in a wall installation However...

Page 8: ...along the knee braces Using a carpenter s level or a straight edge determine the height of the retention bracket in relation to the resting surface of the heater Once you ve determined that mark loca...

Page 9: ...the two sections until the flange on part A meets the inside of the window frame and the flange on part B meets the side of the heater Using a drill with a 5 16 socket bit drive the self tapping scre...

Page 10: ...ater install the Knee Support Braces Install the knee support braces supplied See the previous page for installation You may use the hardware supplied or purchase the appropriate fasteners from your l...

Page 11: ...ON OFF as well as adjustments for the fuel feed rate is performed by pressing the appropriate button s on the control panel which is located on the front lower left hand corner of your heater ON OFF...

Page 12: ...arting the appliance 6 Make sure that the viewing door and combustion door is securely closed the safety switch will not allow the heater to feed fuel if they are left open 7 Press the ON button on th...

Page 13: ...in this unit as indicated can result in poor performance safety hazards and void your warranty Unplug your heater s electrical cord prior to removing the back panel or opening the exhaust system for a...

Page 14: ...of the correct size and thickness DO NOT substitute alternative materials for the glass Contact your authorized dealer to obtain this glass For the glass in the front door bend the two tabs up and rem...

Page 15: ...lid is closed completely Auger system is jammed or there is a bridging of the fuel in the hopper preventing fuel from flowing into the auger feed system PROBLEM CAUSE Auto Start Igniter fails to igni...

Page 16: ...16 Ussc 42 39 40 41 39 LEFT SIDE RIGHT SIDE FILLER PANELS FOAM INSULATOR PANEL CUT TO SIZE 43 Parts Diagram...

Page 17: ...80549 Switch Pressure 1 20 891121 Hose Silicone 1 FT 21 89586 Nipple Auger 1 22 80545 Controller Board Assy 1 23 80555 PWA Display Board 1 24 80550 Keypad Assembly 1 N S 80544 Wiring Harness Main 1 N...

Page 18: ...18 Ussc Wiring Diagram...

Page 19: ...Ussc 19 Notes...

Page 20: ...ve the full model number which is on the nameplate attached to the heater When ordering repair parts always give the following information as shown in this list 1 The part number 2 The part descriptio...

Reviews: