When Installing your heater in an exterior wall
• Select a wall to the exterior of the building. This wall should
have the required clearance to combustibles inside and out
mentioned earlier in this manual. Make certain that electrical
wires, conduit, water or gas pipes do not pass through the area
you have selected
• USSC suggest the following installation illustrated to the right,
however, you may frame the hole cut out to your discretion.
A sturdy base for the heater to rest should be established.
•
At the desired height, mark the hole location for your heater.
Measure and cut the appropriate size hole for your installation.
The cut out should border a wall stud. The next wall stud will
need to be cut.
Build a frame of 2 x 4’s at the dimensions suggested and secure
it in place by attaching it to the available studs.
• Before installing the heater, install the Knee/Support Braces.
• Install the knee/support braces supplied. See the previous page for installation. You may use the hardware
supplied or purchase the appropriate fasteners from your local hardware store for the type of material you
are securing into.
• Seal around the heater with silicone or caulking to protect against the weather.
[648mm]
[572mm]
[356mm]
[432mm]
WARNING! - DO NOT INSTALL IN A SLEEPING ROOM
CAUTION! - THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL, AND CEILING/ROOF MUST BE
MAINTAINED.
• The heater must be permanently attached to the wall.
• The heater must be electrically grounded to the steel chassis of the mobile home with 8 GA copper wire
using a serrated or star washer to penetrate paint or protective coating to ensure grounding.
• When moving your mobile home, the heater must be removed while the mobile home is being relocated.
After relocation, heater may be reinstalled and securely fastened.
• Check with your local building officials as other codes may apply.