38
67XXU USB/Serial Scale Service Manual
PRIM.Ut
kg
lb
Primary unit
Select the primary unit from kg or lb.
The second unit is lb if kg is
selected as the primary unit.
*
The calibration standard weight
must be in the primary unit!
lb
SECD.N
100-25000
Second scale full scale
value
The division number under second
unit. The maximum is
1.25*(PRIM.N).
*If (REGUL)
≠
none, the max is
10,000
NOTE: Secondary division has to
match the primary division.
10.DSP
NO
NO
Display weight at 10
times division number
under primary unit
*If (REGUL)= none this parameter
will not be available.
When yes is selected, some
menus will not be active.
YES
MOTON
1-255
4
Motion window
1-255 = ±0.25d *(1-255)
*If (REGUL)=none, the max is 12
OVER.D
0-100
0
Overload display
limitation
0=FS+9d
1-100=101%FS -200%FS.
*If (REGUL)=none, the max is 10
UNITS
KG
yes
yes
UNITS key
YES = enable this unit
No = disable this unit
In trade applications, lb:oz is not
allowed
no
lb
yes
yes
no
oz
yes
yes
no
lb:oz
yes
no
no
g
yes
yes
no
CONFG
SubMenu1
SubMenu2
Option
Default
Parameter Description
Comment