BreatheAudio BA-6640 Installation Manual Download Page 15

VARIABLE

OUTPUT

FIXED

OUTPUT

ZONE 1

TIP=L

RING=R

VARIABLE

OUTPUT

FIXED

OUTPUT

ZONE 2

TIP=L

RING=R

VARIABLE

OUTPUT

FIXED

OUTPUT

ZONE 3

TIP=L

RING=R

SOURCE LINK

L

R

L

R

L

R

SOURCE INPUTS

1

2

3

4

5

6

1

2

3

4

5

6

CONNECT TO

BA-6640X

USE BA-SLC1

CABLE

ZONE 1

14

XVI. Pulse BA-200 200 Watt Auxiliary Amplifier

The BA-200 is specifically designed for use with the Breatheaudio Systems'
lineouts. It can be used with either the fixed or variable lineouts on the Elevate
6.6 with either a 1/8” (3.5mm) to 1/8” stereo patch cable or a 1/8” stereo
to RCA patch cable, Fig 18.

An additional feature of Elevate 6.6 is zone specific triggers that will trigger the
BA-200 only when that zone is turned on.

Utilizing the voltage trigger requires a mono 1/8” (3.5mm) patch cable from
either the System ON output on the Elevate 6.6 to the BA-200 Voltage trigger
input, or from the specific Zone Trigger on the Elevate 6.6 to the Voltage
Trigger on the BA-200, Fig. 19.

ZONE 6

ZONE TRIGGER OUTPUTS

EMITTER OUTPUTS

ZONE 5

SUM1

1

2

2

3

1

3

5

2

4

6

SUM2

5

4

5

6

Elevate 6.6
Amplifier

Fig. 18

Fig. 19

Elevate 6.6 Amplifier

RS232 Interface

The RS232 port allows external two-way communication with the Elevate
6.6 System. This can be used in conjunction with the many home automation
control systems available on the market today to operate Elevate 6.6. The
RS232 addendum contains the necessary command sets for communication
with the Elevate 6.6 System.

BA-200 Amplifier

CONTROL

AUDIO

OUTPUT POWER

SPEAKER

INPUT

8 OHM: 70W X 2
4 OHM: 100W X 2

LEFT

RIGHT

-

-

+

+

BA-200 Amplifier

CONTROL

AUDIO

OUTPUT POWER

SPEAKER

INPUT

8 OHM: 70W X 2
4 OHM: 100W X 2

LEFT

RIGHT

-

-

+

+

Summary of Contents for BA-6640

Page 1: ...BA 6640 Installation Manual E X P E R I E N C E T H E R H Y T H M O F Y O U R L I F E Six Source Six Zone Audio Distribution System ...

Page 2: ...closure that will impede the flow of cooling air 8 Do not install this product near any heat sources such as radiators heat registers stove or other apparatus including heat producing amplifiers that produce heat 9 Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third g...

Page 3: ...exemple baignoires éviers piscine sous sol humides Etc ée cela Protéger pincement particulièrement au niveau des fiches des réceptacles utilisés et à l endroit de sortie de l appareil Ne pas casser la fiche de terre du cordon d alimentation 11 Utiliser uniquement les accessoires spécifiés par le constructeur 12 Utiliser uniquement avec le chariot de transport le support le trépied la console ou la...

Page 4: ...PKeypadswithwhite ivory almondandblackinserts andtrimplates 1 BA 6640APAllportConnectionHub 1 BA 6640APCAllportCable 6 BA VECVisibleLEDIRemitters 1 BA NC1Networkcable 1pr BA REMdoublespacerackearmounts 1 BA PC2 NAPowercable 2wire NorthAmericaonly Elevate 6 6 Wiring Diagram BA 6640XSExpanderPackageContents Qty Description 1 BA 6640X6zoneexpanderamplifier 6 BA 6640KPKeypadswithwhite ivory almondandb...

Page 5: ...zonehasbeen activated Keypad Features 1 Volume Level 2 Power 3 Volume 4 IR Receiver 5 Mute 6 Source Selection Buttons ThelevelofthezonevolumeisindicatedbytheseLEDs light emittingdiodes Thepowerbuttonturnsthatkeypad szoneonandoffindependentlyoftheotherzones Pressingandholdingthepowerbuttonturns allzonesoffsimultaneously Independentaudiovolumelevelforeachzoneiscontrolledwiththesebuttons Eachkeypadha...

Page 6: ...vate6 6 Expander package TheRS232serialportallowstwo waycommunicationforcontrolbyahomeautomationsystem AdetachablepowercablesuppliespowertotheElevate6 6SystemfromanyACoutlet Zone Triggers Emitter Outputs Speaker Outputs Theseoutputsprovidea12 voltoutputwhenthecorrespondingzoneisturnedon Thisisusedtotriggerexternalequipment specifictoagivenzone TheseoutputstransferIR infrared signals repeatedfromaz...

Page 7: ...ectcolorschemeasshowninFig 1 3 Flattenthewiresintheircorrectorder andtrimthemevenlyacross thetop Mostcrimptoolshaveawiretrimmerbuilt in Itisbestto trimthewirestoabout inlength 4 Whileholdingthewiresflatbetweenyourthumb andforefinger insertthewiresintotheRJ45connector soeachisinitsownslot PushthewireintotheRJ45 soall8conductorstouchtheendof theconnector Theinsulationjacketshouldextendbeyondthe crim...

Page 8: ...yinanaudiorack entertainment centeroraclosetdedicatedtohousingthehomeaudio videoequipment ThisactivatestheinternalprotectivecircuitryoftheElevate6 6 System III Installing the BA 6640AP Allport TheAllportisamulti connectionhubdesignedtoacceptalltheCAT5and speakerwiresfromthekeypadsinthesystem BoththeBA 6640MSmain systemandtheandtheBA 6640XSsixzoneexpandersystemhaveanAllport includeddesignedforuptos...

Page 9: ...ckoftheElevate6 6amplifier Fig 5 Source 1 Tuner 1 Audio Out VI Connecting the IR Emitters IRcommandsforthesourceequipmentaretransferredfromtheElevate6 6 amplifiertothesourceequipmentviaminiIRmouseemitters Sixoftheseare suppliedwithyourElevate6 6System Theemitterispluggedintothe correspondingsourceIRoutputontheElevate6 6andthenplacedovertheIR receiverwindowonthesourcecomponent fig 6 TheIRoutputsare...

Page 10: ...if it is set while keypad is plugged into the CAT5 Source Link Cable Data Link Cable Fig 9 Fig 7 Fig 8 9 012 3 4 5 6 7 8 9 A B C D EF Elevate 6 6 Keypad Model BA 6640KP www breatheaudio com Breatheaudio LLC Hebron Kentucky USA Use only with Breatheaudio System Elevate 6 6 Utiliser uniquement avec Breatheaudio System Elevate 6 6 WARNING AVIS Zone Address Network Connection Local Source VARIABLE OUT...

Page 11: ...ablesthegroupfunction andVolumeDowndisablesthegroupfunctionand causesthekeypadtooperateindependentlyofallothergroups fig 12 FLAT 4 dB 4 dB 6 dB 8 dB 6 dB 8 dB Fig 11 GroupDisabled GroupEnabled Fig 12 VOL VOL VOL VOL IX Keypad Zone Settings EachElevate6 6keypadhastheabilitytosetspecificzonefunctions These arebassandtrebleEQ sourcegrouping allon partymode andvolumereset Eachofthesefunctionsisaccesse...

Page 12: ...14 Fig 15 Volume Reset Eachzonehasthecapabilityofturningonattwodifferentvolumelevel settings Atfactorydefaultthezonewillturnonatthepreviouslisteninglevel Ifdesired youcanchangethatdefaulttoalowlevelvolumeresetregardless ofthepreviouslevel Tochangethezonetovolumeresetmode presstheMuteandSource5 buttonssimultaneously TheSource5buttonwillbeginflashing Thevolume LEDwillfirstappearatthefarleftindicatin...

Page 13: ...TPUT FIXED OUTPUT ZONE 1 TIP L RING R VARIABLE OUTPUT FIXED OUTPUT ZONE 2 TIP L RING R VARIABLE OUTPUT FIXED OUTPUT ZONE 3 TIP L RING R VARIABLE OUTPUT FIXED OUTPUT ZONE 1 TIP L RING R SYS ON EXT MUTE SYSTEM ZONE TRIGGER OUTPUTS SOURCE LINK L R L R L R SOURCE INPUTS NETWORK SUM1 EMITTER OUTPUTS DIGITAL LINK 1 2 3 4 5 6 1 2 3 4 5 6 1 2 4 3 5 1 2 3 CONNECT TO NV E6DX USE NV SLC1 CABLE CONNECT TO BA ...

Page 14: ...EQUIPMENT TO RAIN OR MOISTURE ARIN D EVITER LES DANGERS D INCENDIE ETD ELECTROCUTION NE JPAS EXPOSER CET APPAREIL A LA PLUIE NIAL HUMIDITE USE ONLY WITH 250V FUSE USE ONLY WITH 250V FUSE 3033118 C US INTERTEK CM CONFORMS TO UL STD VARIABLE OUTPUT FIXED OUTPUT ZONE 1 TIP L RING R VARIABLE OUTPUT FIXED OUTPUT ZONE 2 TIP L RING R VARIABLE OUTPUT FIXED OUTPUT ZONE 3 TIP L RING R VARIABLE OUTPUT FIXED ...

Page 15: ...hevoltagetriggerrequiresamono1 8 3 5mm patchcablefrom eithertheSystemONoutputontheElevate6 6totheBA 200Voltagetrigger input orfromthespecificZoneTriggerontheElevate6 6totheVoltage TriggerontheBA 200 Fig 19 ZONE 6 ZONE TRIGGER OUTPUTS EMITTER OUTPUTS ZONE 5 SUM1 1 2 2 3 1 3 5 2 4 6 SUM2 5 4 5 6 Elevate 6 6 Amplifier Fig 18 Fig 19 Elevate 6 6 Amplifier RS232 Interface TheRS232portallowsexternaltwo w...

Page 16: ...padschangewhenasourceisselected ononlyone ThekeypadsaresetforSourceGrouping PressingtheMUTEandSource3button simultaneouslysetstheSourceGroupingfeature Thiswillcausemultiplekeypadstoalwaysshare thesamesource seeSectionIX ZoneEQand SourceGroupingonpage11 Withthekeypadspluggedin thePOWERLEDonthe frontoftheamplifierwillnotturnon OneormoreimproperlywiredCAT5cables Makesuretheamplifieristurnedon Testtha...

Page 17: ...Listing CAN CSAE60065 00 Source Inputs 1 6 CEListing SEMKO EN60065 EN55013 inputImpedance 10K EN55020 EN6100 3 2 EN6100 3 3 A1 InputSensitivityforratedpower 300mV RMS InputOverload 3V RMS Physical Specifications UnitSizeMillimeters 88Hx430Wx325D Emitter Outputs UnitSizeInches 31 2Hx17Wx123 4D SourceOutputs 6 ShippingSizeMillimeters 290Hx540Wx440D SumOutputs 2 ShippingSizeInches 113 8H x211 4 Wx173...

Page 18: ... owner s manual If no keypad is connected with a given zone address then ZoneSet will default to A OR0 No override B BASS 0 Bass FLAT C TREB 0 Treble FLAT D GRP0 SOURCE GROUPING OFF E VRST1 VOLUME RESET TO 50 dB ON If these zone settings are overridden by the commands which follow in this document the overridden values will reset to the default values above upon cycling power on the Main Unit 3 Fo...

Page 19: ...s zone is PARTY MASTER zzz SLV if this zone is SLAVED to a PARTY MASTER in another zone zzz OFF if this zone is under LOCAL CONTROL only either there is no party master or this zone has been manually overridden This response will also be issued in response to pressing the ON OFF VOLUME or SOURCE keys on a KEYPAD NOTE the response will be issued if a SOURCE key is pressed on a zone that is powered ...

Page 20: ...RIDE state but other RS232 commanded settings will remain until another RS232 command overrides them or power is cycled This response is also issued whenever these parameters are set from a keypad COMMAND Turn zone xx ON RESPONSE Same response as for COMMAND Turn zone xx OFF RESPONSE Same response as for COMMAND Turn ALL zones OFF RESPONSE This RESPONSE is also issued when ALL OFF is pressed on an...

Page 21: ... dB include lead 0 for all single digit values RESPONSE Same response as for COMMAND STARTS zone xx volume ramp UP at the rate of 10 dB per second in 1 dB steps This is the same as holding VOLUME UP key on a KEYPAD for 1 second RESPONSE Same response as for COMMAND STARTS zone xx volume ramp DOWN at the rate of 10 dB per second in 1 dB steps This is the same as holding VOLUME UP key on a KEYPAD fo...

Page 22: ...URCE GROUP OFF RESPONSE NOTE sending this command to the will override the non volatile GROUP setting set from keypad for this zone until power is cycled COMMAND zone xx VOLUME RESET ON RESPONSE NOTE sending this command to the BA 6640 will set override lock out KEYPAD non address DIP switches for this zone until power is cycled COMMAND zone xx VOLUME RESET OFF RESPONSE NOTE sending this command t...

Page 23: ... version number RESPONSE Issued whenever the External MUTE first activates closure to ground and 0 whenever the External MUTE de activates open connection to ground NOTE there is no COMMAND associated with this response it is always initiated by a change at the EXT MUTE input RESPONSE Issued whenever External MUTE de activates open connection to ground NOTE there is no COMMAND associated with this...

Page 24: ...2395 Arbor Tech Dr Hebron KY 41048 USA 866 889 1019 www breatheaudio com 0728 ...

Reviews: