EN
E
Copyright Bravilor Bonamat B.V.
2
2.
TECHNICAL DATA
READ
!
Read the safety manual (700.403.713)
2.1
General
Type I (Model Chill
−
003)
: Standard
Type II (Model Chill
−
004)
: With CO
2
Weight (without water)
: 16 Kg / 38.6 lb
2.2
Transport dimensions and weights
Transport dimensions (l x h x w)
: 19.69 x 17.13 x 14.17 (inch)
Transport weight
: 17.5 Kg / 38.6 lb
2.3
Dimensions
Device dimensions (l x h x w)
: 17.72 x 14.96 x 11.02 (inch)
2.4
Electrical system
TIP
−
See the identification label for correct values.
Supply voltage and Frequency
: 120 V~ / 60 Hz
Input power
Chill
−
003
: 228 W
Chill
−
004
: 240 W
Input current
Chill
−
003
: 1.9 A
Chill
−
004
: 2.0 A
Low water pressure protected switch
: 100 kPa (Min. operation pressure)
Class
: 1
2.5
Water system
Min. water pressure (supply)
: 150 kPa (1.5 Bar)
Max. water pressure (supply)
: 600 kPa (6 Bar)
Cold
−
water reservoir volume
:
0.4 Gal
Hourly capacity cooling system
: approx. 2
−
3 Gal/hour, at a water
−
supply
temperature of 77
F
Water temperature adjustable range
: 41
−
68
F
2.6
Pressure for Carbonation system
Input CO
2
pressure
: 300
−
400 kPa (3.0
−
4.0 Bar)
2.7
Refrigerant
R134a
: 2.87 fl oz
2.8
Recommended cleaning fluids and liquid disinfectants
Cleaning agent for the exterior
: normal, non
−
abrasive or corrosive detergent.
Liquid disinfectants for the
cold
−
water reservoir and outlet
: CoolerClean Rinse (www.coolerclean.com)
hydrogen peroxide solution (5%)
CAUTION!
−
Before use, first read the instructions on the packaging of the cleaning agent.