WARNING:
The following points must be carefully observed:
•
Protect the unit from too high or too low temperatures. The unit works reliably in
a temperature range of -15°C to 50° Ceslsius.
•
Protect the unit from excessive shock or vibrations. It might be necessary to
mount the unit with suitable shock absorbing materials.
•
Protect the unit from dirt and moisture and all kinds of oils and gasoline.
•
The display must be easy to read, protect the unit from glare and ensure a good
field of view.
•
Mount instrument as far away from radio / transponder antennae as possible.
All points must be observed for longevity and reliability!
2.3 Electrical Connections
If you have never before installed electrical instruments and you are not exactly sure
what to do, please ask someone who has experience to help you with the installation.
When working with senders, please handle carefully, as they are sensitive electronic
parts.
Only use high-quality cables (highly flexible, stranded and shielded) and connectors.
Check that your cables run untangled and clean. Disconnect the aircraft battery before
working on electrical components!
Ni-Cr-Ni temperature senders require special cables which are supplied with the
senders!
WARNING:
All wires should be protected by small metal terminals to ensure a
lasting and safe connection to the
ALPHA
MFD
. All cables and the Pitot tube
should be secured against pull. There is a special mounting bracket on the rear
of the
ALPHA
ALPHA
ALPHA
ALPHA
MFD
for securing against pull.