35
If you want to change a function, press the >
ENTER/MEMO
< key. Now the >SET<
icon starts to flash which indicates that a value or setting can be changed by pressing
the >ARROW< keys. Pressing the >
ENTER/MEMO
< key again stores the new
setting. If the new settings shall not be stored, press >
FUNC/SET
< instead of
>
ENTER/MEMO
<. Also if you want to leave the SET-Mode, press >
FUNC/SET
<.
WARNING!
For safety reasons the you cannot switch to SET-Mode if the
ALPHA
MFD
measures an Air Speed of 50 km/h and above.
8.1 Restore Factory Settings
In SET-Mode 40 the
ALPHA
ALPHA
ALPHA
ALPHA
MFD
can be reset to default factory settings. All settings
with a * in the list below will be restored to the default values. This
Reset
also helps if
your
ALPHA
ALPHA
ALPHA
ALPHA
MFD
shows some unexpected behaviour.
8.2 SET-Mode Settings
No. Remarks
Text in Display
Setting
Default Value
1
Actual Fuel Capacity
ACTUAL FUEL IN
TANK
Numerical
100 (*)
2
Maximum Fuel Capacity
MAX FUEL TANK
CAPACITY
Numerical
100 (*)
3
Fuel Flow Calibration
FUEL FLOW
CALIBRATION TO
ENGINE %
Numerical
100 (*)
4
Engine Hour Meter
ENGINE HOURS
Numerical
5
AGM Range
AGM RANGE +/-
Numerical
100 m (*)
6
Stall Alarm
STALL ALARM
Numerical
Can be Locked #
7
Velocity never to exceed
Vne
Numerical
Can be Locked #
8
EGT Alarm
EGT ALARM
Numerical
680 °C (*)
9
CHT Alarm
CHT ALARM
Numerical
150 °C (*)
10 Oil Temp Alarm
OIL TEMP ALARM
Numerical
150 °C (*)
11 Water Temp Alarm
WATER TEMP
ALARM
Numerical
95 °C (*)
12 RPM Alarm Threshold
RPM ALARM
Numerical
7000 (*)
13 Oil Press Minimum Threshold
MIN OIL PRESSURE Numerical
1 bar
14 Oil Press Max Threshold
MAX OIL PRESSURE Numerical
8 bar (*)
15 Calibration Air Speed
AIR SPEED
CALIBRATION %
Numerical
Can be Locked #
16 Speed Zero of Air Speed
Indicators
AIR SPEED ZERO
ZERO
17 Pointer Style (Single Pointer or
Section)
POINTER STYLE
See Vario
Display
Section (*)
18 RPM Factor Adaptation
RPM FACTOR
*1,*2,*4,
/2, /4, /6
*1 (*)
19 Time
SET TIME
12:34
12:00
20 Date
SET DATE
01:01
01:01