Page 14
AI/fold-out art
1-92
Unfold for:
Lift Electrical Schematic
Lift Wiring Diagram
OR(16)
OR(16)
1
2
1
2
RD(16)
OR/BK(20)
WH/VT(20)
OR/BK(20)
WH/VT(20)
BK/BU(20)
RD(16)
WH(16)
BK(16)
BK(16)
OR(16)
BK/OR(16)
OR(16)
BK/OR(16)
Strobe / Alarm
Valve Block
34774A
34298A
100524-002
34571A-1
38135A
34818A
401035A
400285A
400625A
1
2
BLUE(20)
ORANGE(26)
WHITE(26)
ORANGE(20)
RED(22) & RED(20)
GREEN(26)
6
5
4
3
2
1
COLOR
NO.
12-COND WIRE CODE
BLACK(26)
YELLOW/RED (20)
WHITE(20)
9
BLACK(20)
10
NOT USED
11
BLUE(26)
12
8
7
RED(16)
YELLOW(16)
BROWN(16)
GREEN(16)
4
BLACK(16)
5
NOT USED
6
3
2
1
COLOR
NO.
SOLENOID D
SOLENOID C
SOLENOID B
SOLENOID A
4
BK(18)
5
NOT USED
6
3
2
1
COLOR
NO.
6-COND WIRE CODE
6-COND WIRE CODE
34819A
24V
GND
34392A
37107A
37029
37258A
(Braun Replacement)
OEM Supplied
To
Ground
Stud
To
Ground
Stud
To
OEM 60A
Mega Fuse
To
Ground
Stud
Detail below shows two different
styles of diode identification.
BK(6)
BK(6)
Up/Stow/Deploy
Solenoid
Ultrasonic
Sensor
1
2
RD(16)
BK(16)
RD(16)
BK(16)
BK(16)
BK(16)
2 1
OR(20)
OR(20)
OR(18)
OR(20)
BK(18)
BK(18)
OR(22)
BK(18)
BK(16)
RD(16)
GN(16)
BN(16)
YL(16)
OR(20)
1
2
3
1
2
3
6
5
4
1
2
3
6
5
4
NOT USED
BLACK/BLUE(20)
WHITE/VIOLET(20)
ORANGE/BLACK(20)
4
NOT USED
5
NOT USED
6
3
2
1
COLOR
NO.
WHITE(16)
BLUE(16)
BLACK(16)
BROWN(16)
4
YELLOW(16)
5
WHITE(16)
6
3
2
1
COLOR
NO.
6-COND WIRE CODE
6-COND WIRE CODE
1
2
3
6
5
4
1
2
3
6
5
4
YELLOW(26)
BLACK(26)
RED(26)
GREEN(26)
ORANGE(26)
BLUE(26)
WHITE(26)
6
5
4
3
2
1
COLOR
NO.
7-COND WIRE CODE
7
WHITE(22)
RED(22)
VIOLET(22)
BLACK(22)
GREEN(22)
BLUE(22)
ORANGE(20) & ORANGE(22)
6
5
4
3
2
1
COLOR
NO.
7-COND WIRE CODE
7
YELLOW / BLACK(18)
YELLOW / WHITE(18)
ORANGE(22)
DARK BLUE(18)
4
3
2
1
COLOR
NO.
4-COND WIRE CODE
3
4
1
2
RED(22)
VIOLET(22)
GREEN(22)
BLACK(22)
BLUE(22)
WHITE(22)
4
3
2
1
6
5
COLOR
NO.
6-COND WIRE CODE
4
5
1
2
6
3
37259A
34695A
34700A
34769A
34699A
34737AM
BK(18)
RD(18)
RD(18)
RD(20)
RD(20)
RD(22)
GN(22)
BK(22)
BK(18)
1
2
1
2
3
1
2
1
2
BK(22)
GN(22)
WH(20)
BU(20)
OR(20)
RD(20)
RD(20)
RD(20)
YL/RD(20)
BK(20)
RD(22)
1
2
3
YL
/ WH(18)
DK BU(18)
YL
/ BK(18)
1 2 3
1
2
3
4
RD(22)
RD(22)
BK(26)
RD(26)
RD(22)
RD(22)
WH(24)
BN(24)
BK(22)
RD(22)
BU(26)
GN(22)
BK(22)
RD(22)
GN(22)
GN(22)
RD(22)
RD(22)
BK(22)
RD(20)
RD(20)
OR(26)
WH(26)
GN(26)
1
2
1
2
1
2
3
2
1
2
1
2 1
2 1
3
2
1
Stow Level
Microswitch
Full Out
Microswitch
Full In
Microswitch
Floor Level
Microswitch
To
Lift
Stowed
Interlock
To
Vehicle
Interlock
Inner Roll Stop
Deployed
Microswitch
COM
NO
NC
COM
NO
NC
COM
NO
NC
COM
NO
NC
COM
NO
NC
RD(22)
BK(22)
Platform Unfold
(Occupied)
Microswitch
Inner Roll Stop
Occupied Switch
Outer Barrier
Occupied
Switch
COM
NO
NC
34778A
RD(22)
BK(22)
BU(20)
BK(20)
WH(24)
BN(24)
or
D
A
C
B
BU(18)
BU(18)
BU(18)
BU(18)
OR/BK(20)
WH/VT(20)
1
2
GND / PWR
M
AT
INTERLOCK
HAND PENDANT
LIFT INPUTS
ALARM
B-UP
B-DOWN
L-OUT
L-IN
VALVE
PUMP
JUMPER
NOTES:
1. Junctions occur only at
marked intersections.
2. Lift shown in stowed position.
OEM Supplied
1
2
4
5
7
8
3 6 9
10
11
12
1 2
3 4 5
6 7
1
3 4 5
6 7
2
2 1
5 4 3
7 6
1
3
4
5
6
7
2
OR(26)
BU(26)
Stow/Deploy
Switch
YL(26)
BK(26)
GN(26)
WH(26)
RD(26)
L
G
Up/Down
Switch
Switch Box
(As Viewed From Terminal
Side of Switch)
SOLID BUS(20)
Interlock
LED
+
-
Lift Power