Each workstation must be equipped according to the
recommendations with the necessary static protective measures,
if ESD components or boards are handled.
Each workstation must be equipped with a conductive table
surface. The conductive surface, the soldering iron or the
soldering stations must be grounded via protective resistors.
Chairs must be of antistatic design. The floor or floor mats should
be of electrically conductive material.
Personnel must wear conductive wristbands which are connected
to a central ground potential via protective resistors, e.g. the
ground contact of a wall outlet. Furthermore it is recommended
that personnel wear cotton clothing and electrically conductive
shoes to prevent electrostatic charge.
Spare Parts and Test Equipment
Only use original spare parts from the manufacturer. Do not
tamper with assembly groups which can only be exchanged
completely. The spare parts required are listed in the repair
descriptions.
Service personnel are responsible for the calibration of their test
equipment. Original test equipment can be calibrated at the
works of B. Braun. Further information is available upon request.
Setting Off
Additional notes and warnings are set off as follows:
Note
Is used for additional or special notes concerning information and
working steps.
CAUTION
Is used for working steps which may result in damage to the unit,
system or to a connected device.
WARNING
!
IS USED FOR WORKING STEPS WHICH MAY RESULT IN PERSONAL
INJURY.
Fig.: 0 - 1
Summary of Contents for perfusor compact
Page 1: ...Perfusor compact Service Manual 0 10 3 1 0 Version 3 1 English...
Page 10: ...Contact Persons 0 0 10 Perfusor compact 2 1 gb For your notes 2 1...
Page 14: ...System Overview 1 1 4 Perfusor compact 2 1 gb For your notes 2 1...
Page 20: ...Software 2 2 6 Perfusor compact 2 1 gb For your notes 2 1...
Page 56: ...Unit Elements 4 4 18 Perfusor compact 2 1 gb 2 1 For your notes...
Page 62: ...Checks after Repair 5 5 6 Perfusor compact 2 1 gb 2 1 For your notes...
Page 64: ...Maintenance 6 6 2 Perfusor compact 2 1 gb For your notes 2 1...
Page 72: ...Procedural Instructions on the TSC 8 8 6 Perfusor compact 2 1 gb 2 1 For your notes...
Page 74: ...Test Equipment and Special Tools 9 9 2 Perfusor compact 2 1 gb For your notes 2 1...
Page 78: ...Spare Parts List 10 10 4 Perfusor compact 2 1 gb For your notes 2 1...
Page 80: ...Revision Documentation 11 11 2 Perfusor compact 2 1 gb 2 1...
Page 85: ......