Page 19
Item
Qty.
Part No.
Description
1
1
18189A
Circuit Sentry Bkt. Assy.
includes:
2a
1
18180
• Decal, Installation Instructions
2b
1
18181
• Decal, 100 A Circuit Sentry Label
3
2
10377
• Rivet, Pop, 3/16" x 5/8"
*
2
11541
* Washer, #10 Flat
4
1
18178
• Circuit Breaker, 100 A
5
1
18138
• Bracket, Circuit Sentry
Item
Qty.
Part No.
Description
6
4
10383
Screw, #8-18 x 1/2" Self-Tap
7
1
12764
Plastic, Flat,1/8" x 4" x 4"
8
1
13362A
Lead Wire, #2 Ga. x 30"
9
1
13050
Spacer, 13/32" x 1/2"
10
1
10025
Bolt, 3/8"-16 x 1" Hex
11
1
13865
Terminal, 1/4" Eye
F
i
gure P
* Indicates items not shown
L
i
f
t
In
s
ta
ll
ati
o
n
In
s
t
ruc
ti
o
n
s
Attach the power cable to the
Auxiliary
terminal of the circuit sentry as shown. Attach
one end of the 30" lead wire (item 8 above) to
the
Battery
circuit sentry terminal. Locate the
circuit sentry within 24" of the positive (+)
battery terminal and use self-tap screws to
fasten it to the fenderwell or other appropriate
mounting surface as shown.
Important:
Sandwich the 1/8" x 4" x 4" plastic between
the circuit sentry and the mounting surface to
prevent electrical short circuits.
Note:
A 3/8"-16 x 1" bolt and 13/32" I.D.
spacer are provided for side terminal mount
batteries. Install as shown.
Carefully
connect the opposite end of the 30"
lead wire to the
Positive
(+) post of the
battery.
Use cable ties and/or 7/16" cable clips and
self-tap screws to secure the cable to the
underside of the vehicle (shown in Figure O).
4
Circuit Sentry Installation and Power Connection
WARNING
WARNING
Risk of electrical
shock! Use extra
care when making
electrical connec-
tions.
Risk of electrical fire!
Sandwich 1/8" plastic
between Circuit
Sentry and mounting
surface.
Note:
Circuit Sentry #18190A is
supplied for
24 Volt
Applications.
#13362A
Lead Wire
Connect to
(+) Battery Post
Lift
Power Cable
100 AMP
Circuit Sentry
6
4
3
5
Lift Power Cable
Lead Wire
11
7
10
8
9
Side
Post
Mount
Top Post
Mount
Positive (+)
12 Volt
Battery
Post
Circuit Sentry Termination
Back View
Lead wire (item 8)
Side Post Mount
Application
Lead wire (item 8)
Top Post Mount
Application
This unit is designed to protect the electrical system on
all Braun hydraulic wheelchair lifts. In the event of failure,
wait 60 seconds.
Then turn RESET
lever to reset breaker
.
18181
Rating: 100
Amps
The
B
r
a
u
n
C
i
rc
u
it
Se
nt
ry
CAUTION! T
u
rn RESET lever to reset breaker only!
T
u
rning lever at any other time will result in damage.
1.
Attach lift power cable to
2.
Attach battery lead cable to
3. Locate Circuit Sentry as specified in owner's/service
manual. Use self-tap screws to mount unit to
appropriate mounting surface. Sandwich flat
plastic between Circuit Sentry and mounting surface.
4.
Attach battery lead cable to battery terminal.
auxiliary
battery
Installation Instructions
Note:
positive (+)
Circuit Sentry terminal.
Circuit Sentry terminal.
18180
Aux.
Bat.
Route the lift power cable to Circuit Sentry installation location. Install terminal (item 11).
Connect terminal to Circuit Sentry terminal as shown in the Back View (below).
Auxiliary
2a
2b
HI-AM
P
WATERPROOF
184100P
Buss
100A