5704 - 10
BINC Rev:
11/97
Service Documentation
Service Information
BAG Rev:
8/97
5704
Before starting selftest:
after approx. 0.25 sec
after approx. 0.5 sec
after approx. 0.5 sec
after approx. 0.5 sec
red and green LED illuminated
This is a 5 as version control
The red LED illuminates only, when pad 9
No display, provided that the mains power and motor are still
switched on.
Power supply and battery test
After accomplishing the aforementioned electric test (i.e. in a discharged mode) recharge the
appliance for a period of 15 minutes, then remove it from the power supply.
•
Important! Oil the cutter system.
•
Let the appliance run into a discharged state. After the motor has come to a full stop, the
display must indicate "0".
•
Switch off the appliance.
•
Recharge the appliance control the energy or power consumption respectively by means of
an ammeter (measuring range 0 to 200 mA max.) or a watt meter (measuring range 0 to
200 watts max.). After 90 minutes max. the recharging process is accomplished, and the
appliance switches to the recharged state (ammeter and watt meter needle respectively fall
into the range of "0").
If these values are maintained within this range, the P.C.B. is functional.
Attention:
If the appliance is removed from the power supply for more than 10 minutes after
total recharge is accomplished, a boost charge of approx. 5 minutes will take place
before the appliance switches over to the recharged state.