D521-Manual_EN_Rev07 2017_05_26
Page 15 of 31
Parameter Group P03.xx
Analog Output
Parameter No.
Meaning of Parameter
Setting Range of Parameter
Description of Parameters and their Settings
P03.00
High end of analog output
Range: 00001 .. 99999
(e.g. RPM)
The high end (corresponding to 20 mamps) is programmed by the same
terms as used in step P01.03 (e.g. in RPM).
P03.01
Low end of analog output
Range: 00001 .. 99999
(e.g. RPM)
The low end (corresponding to 0 resp. 4 mamps) is programmed by the
same terms as used in step P01.03.
P03.02
Live Zero
Range: 0 .. 1
The analog signal can be output without or with live zero.
Setting:
0 : " without live zero" = 0...20 mA
1 : "with live zero" = 4...20 mA
P03.03
Output mode
Range: 0 .. 1
Setting:
0 : signal voltage (10 V)
1 : current
(20 mA)
P03.04
Forced output level at
sensor fault condition
Range: 0 .. 2
Setting:
0 : no,
output follows measured speed
1 : min:
output goes to < 0 mamps
2 : max:
output goes to approx. 21 mamps
P03.05
Characteristics of analog
output increasing/decreasing
Range: 0 .. 1
Setting:
0 : normal
(0/4. .20 mA with increasing speed)
1 : inverted
(20...0/4 mA with increasing speed)