page 06
SECTION 2
Programming The Operator
SECTION 3
Quick Reference Guide
8
Setting the Maintenance Flashing
Counter
The operator is equipped with
maintenance flashing counter that
enables you to set the courtesy light to
flash for 2 minutes after a preset
number of cycles have been
completed. This let the user know that
the operator needs a service. The
counter has 9 levels and each levels
accounts for 2000 complete cycles.
To set the maintenance counter press
and hold the “SET” button until the
display shows “P1”. Press the “UP”
button until the display shows “P6”.
Press the “SET” button to enter the
setup mode.
Functions
1
“P1” - Limits Settings
“OP” - Open Limit
“CL” - Closed Limit
2
“P2” - Closing Force Adjustment
“F1” - Most Sensitive
“F5” - Default Setting
“F9” - Least Sensitive
3
“P3” - Setting IR Safety Beams
“H0” - IR Safety Beams Disabled
“H1” - IR Safety Beams Enabled
4
“P4” - Setting Auto-Close Timer
“10” - 10 Seconds - Shortest Setting
“20” - 20 Seconds
“30” - 30 Seconds
“40” - 40 Seconds
“50” - 50 Seconds
“60” - 60 Seconds
“70” - 70 Seconds
“80” - 80 Seconds
“90” - 90 Seconds - Longest Setting
5
“P5” - Auto-Close ON and OFF
“b0” - Auto-Close Disabled (OFF)
“b1” - Auto-Close Enabled (ON)
6
“P6” - Setting The Maintenance
Flashing Counter
“C0” - Maintenance Flashing Disabled
“C1” - Flash after 2000 Cycles
“C2” - Flash after 4000 Cycles
“C3” - Flash after 6000 Cycles
“C4” - Flash after 8000 Cycles
“C5” - Flash after 10000 Cycles
“C6” - Flash after 12000 Cycles
“C7” - Flash after 14000 Cycles
“C8” - Flash after 16000 Cycles
“C9” - Flash after 18000 Cycles
7
“CODE” - Programming The
Transmitters
“Fu” - Memory Full
“dl” - Memory Cleared
“Su” - Search Unit - Waiting for Code to
be programmed
The display will show the current
status. Use the
“UP”
and
“DOWN”
button to move between
“C0”
and
“C9”
. When the desired setting is
reached press the
“SET”
button. The
operator will return to
“STANDBY”
mode to show that the setting is
complete.
Important note:-
The counter is set in 2000 cycle increments.
“C0” - OFF
“C1” - 2000 Cycles
“C2” - 4000 Cycles Up to
“C8” - 16000 Cycles and
“C9” - 18000 Cycles.