page 04
SECTION 2
Programming The Operator
To clear the memory press and hold the
“CODE”
button for 10 seconds. During
this time the display will change to
show
“SU”
and once the memory is
clear the display will show
“DL”
.
Important Note:
Always clear the operator memory on first
installation as the all the transmitter buttons
are coded in, in the factory for testing
purposes.
4
Setting The Force Adjustment
The operator is designed to sense
obstructions under the door. The
operator will stop and reverse
direction if it is obstructed in the down
direction. If it is obstructed in the up
direction the operator stop.
The operator has 9 sensitivity levels
with
“F1”
being the
most
sensitive and
“F9”
being the
least
sensitive. The
default setting is
“F5”
and it should not
be necessary to adjust this setting if the
door is properly balanced.
To adjust the force sensitivity press and
hold the “SET” button until the display
shows
“P1”
. Press the
“UP”
button
once and the display will show
“P2”
.
Press the
“SET”
button to enter setup
mode. The display will show the current
setting. To increase the sensitivity
press the
“UP”
button and to decrease
the sensitivity press the
“DOWN”
button. When the desired sensitivity is
reached press the
”SET”
button and
the operator will return to
“STANDBY”
mode to show that the setting is
complete.
5
Installing Infra Red Safety Beams
The operator is designed to have Infra
Red Safety beams connected as an
optional safety device. The operator
must be set up to be able to function
correctly with this device connected.
PLEASE NOTE:-
An external power
source is needed for the IR Safety
Beams. If a back-up battery is installed
the operator will not close the door
when the mains power is interrupted as
the IR Safety Beams will not be
functioning. The door will have to be
closed manually. If battery back-up is a
requirement it is suggested that IR
Safety Beams are NOT fitted to the
operator.
To install the IR Safety Beams press
and hold the
“SET”
button until the
display shows
“P1”
. Press the
“UP”
button until the display shows
“P3”
.
Press the
“SET”
button to enter the
setup mode.