InfraRed Thermometer User Manual
6
6.Specifications
Response Time:
Spectral Response:
Emissivity:
Over Range Indication:
Polarity:
Diode Laser:
Operating Temp.:
Storage Temp.:
Relative Humidity:
Power Supply:
Weight:
Size:
Safety:
150ms
8~14um
Digitally adjustable from 0.10 to 1.0
LCD will show “-OL”,”OL”
Automatic (no indication for positive polarity);
Minus (-) sign for negative polarity
Output <1mW, Wavelength 630~670nm,
Class 2(II) laser product
0 to 50 (32 to 122 F)
20 to 60
(-4 to 140 F)
10%~90%RH operating, <80%RH storage
9V battery, NEDA 1604A or IEC 6LR61, or
equivalent
290g (10.2 oz)
100 x 56 x 230mm (3.9 x 2.2 x 9.0”)
“CE” Comply with EMC
°C
°
-
°C
°
IR Measurement
TK Measurement
IR Temp. Range
D:S
Resolution
Accuracy
TK Temp. Range
Resolution
Accuracy
-50 to 1050°C (-58 to 1922°F)
30:1
0.1°C(0.1°F)
-50 to -20°C(-58 to -4°F)
-20 to 200°C(-4 to 392°F)
200 to 538°C(392 to 1000°F)
538 to 1050°C(1000 to 1922°F)
-50 to 1370°C(-58 to 2498°F)
-50 to 1370°C
-58 to 1999°F
2000 to 2498°F
-50 to 1000°C
1000 to 1370°C
±5°C(±9°F)
±1.5%±2°C(±3.6°F)
±2.0%±2°C(±3.6°F)
±3.5%±5°C(±9°F)
0.1°C
0.1°F
1°F
±1.5%±3°C(±5°F)
±1.5%±2°C(±3.6°F)