MAINTENANCE _____________________________________________________________ 

 

NOTE:  

To avoid personal injury or damage to the Nitrogen Inflation System, permit only qualified personnel to 

perform maintenance.  

When cleaning or replacing filter elements and automatic float drains, shut 

off the supply air by turning the valve lever on the front of t

he unit to “OFF”.  After the Inlet 

Pressure Gauge reads zero, you can service the filters. 

 
See repair parts breakdown for replacement parts. 
 
 

ALWAYS:

 

Keep Nitrogen Inflation System clean.

 

DAILY:

  

Check the automatic float drain on all filters for proper operation.

 

If the automatic float drain should become stuck open or inoperable, shut off the 
air supply (see NOTE above).  Before servicing let the pressure bleed off from the 
filter.  Remove the bottom cap from the bottom of the filter. The drain can be 
cleaned in hot soapy water.  DO NOT attempt to disassemble the drain.  If the 
drain is still inoperable after cleaning, it will have to be replaced.  When installing 
a new drain, make sure the o-ring is installed on the bottom stem before screwing 
it into the bottom cap.  Finger tighten only. 

 

WEEKLY: 

Clean the automatic float drain on both filters. 

See above. 

 

BI-YEARLY: 

Clean particulate filter element and replace coalescing element. 

___________________________________________________________________________ 

 

 

OWNER’S RECORDS 

Date Installed:   

_______________________ 

Serial number   

_______________________   

Located on back panel 

___________________________________________________________________________

 

 
 
 
 
 
 
 
 
 
 

 

 
 
 
 

Summary of Contents for 350M

Page 1: ...Branick Industries Inc 4245 Main Avenue Fargo North Dakota 58103 REV010115 P N 81 0227 Installation Operation Repair Parts Information MODEL 350M NITROGEN INFLATION SYSTEM...

Page 2: ...tuation which if not avoided may result in damage to property or minor personal injury HAZARD A source of potential injury to a person MAINTENANCE Those actions that preserve the correct and proper co...

Page 3: ...n Purity When supply air pressure increases increases When supply air flow decreases N2 output flow will decrease When supply air temperature decreases Nitrogen Purity When supply air pressure decreas...

Page 4: ...line to the deoxygenated air outlet on the side of the unit NOTE The Nitrogen generator has a filter system that captures oil water and other contaminants However if your air supply system generates...

Page 5: ...le shut off the air supply see NOTE above Before servicing let the pressure bleed off from the filter Remove the bottom cap from the bottom of the filter The drain can be cleaned in hot soapy water DO...

Page 6: ...5 REPAIR PARTS _____________________________________________________________...

Page 7: ...3 8 NPT HEX NIPPLE 18 1 60 0139 REDUCER 19 2 60 0167 2 1 2 0 300 PSI GAUGE 20 1 60 0171 1 4 UNION TEE 21 5 60 0175 1 2 TUBE TO 3 8 NPT M ELBOW 22 1 60 0176 1 2 TUBE UNION TEE 23 3 60 0177 1 2 TUBE X 3...

Page 8: ...returned for inspection Service or Repair Warranty service or repairs must be performed by a Branick designated service company Membranes replaced under warranty will remain under warranty for the re...

Reviews: