Branick 350M Installation, Operation & Repair Parts Information Download Page 4

  3 

INSTALLATION INSTRUCTIONS _______________________________________________ 

 

1.  Unpack and remove unit from shipping carton and pallet. 
2.  Inspect the unit for any visible damage. 
3.  Make sure the installation location is free from explosion or fire hazard and is a suitably ventilated; 

otherwise, ventilate the area periodically during use of the equipment. 

4.  Make sure the plumbing from the air compressor to the Nitrogen Generator is made of an appropriately 

rated copper, steel or aluminum and is at least 30 ft. in length. 

5.  Install on a solid level wall. 
6.  Anchor the unit to the wall with 3/8 anchor bolts (not supplied) utilizing the four mounting tab holes on the 

back of the unit. 

7.  Connect the 

air

 supply line to the inlet on the side of the unit. 

8.  Connect the 

nitrogen

 supply line to the deoxygenated air outlet on the side of the unit. 

 

NOTE: 

The Nitrogen generator has a filter system that captures oil, water and other contaminants.  However, if your 
air supply system generates an excessive amount of water, etc., it may be desirable to install an air dryer. 
 

NOTICE: 

The presence of any oil in the Nitrogen Membrane will void the 

manufacturer’s warranty. 

 

OPERATING INSTRUCTIONS _________________________________________________ 

 

1. 

Slowly

 

rotate valve lever on the front of the unit, from the “OFF” position to the “ON” position. 

2.  Nitrogen is now being produced and vehicle tires can then be filled or a N

2

 storage tank can be filled.  

3.  To sample the nitrogen purity the nitrogen generator is producing, use the optional nitrogen analyzer and 

check it at the sampling port (front panel, above the ON/OFF valve) just as you would check a nitrogen 
filled tire. 

4.  When not in use, 

Slowly 

rotate valve lever on the front of the unit, from the “ON” position to the “OFF” 

position. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 

Summary of Contents for 350M

Page 1: ...Branick Industries Inc 4245 Main Avenue Fargo North Dakota 58103 REV010115 P N 81 0227 Installation Operation Repair Parts Information MODEL 350M NITROGEN INFLATION SYSTEM...

Page 2: ...tuation which if not avoided may result in damage to property or minor personal injury HAZARD A source of potential injury to a person MAINTENANCE Those actions that preserve the correct and proper co...

Page 3: ...n Purity When supply air pressure increases increases When supply air flow decreases N2 output flow will decrease When supply air temperature decreases Nitrogen Purity When supply air pressure decreas...

Page 4: ...line to the deoxygenated air outlet on the side of the unit NOTE The Nitrogen generator has a filter system that captures oil water and other contaminants However if your air supply system generates...

Page 5: ...le shut off the air supply see NOTE above Before servicing let the pressure bleed off from the filter Remove the bottom cap from the bottom of the filter The drain can be cleaned in hot soapy water DO...

Page 6: ...5 REPAIR PARTS _____________________________________________________________...

Page 7: ...3 8 NPT HEX NIPPLE 18 1 60 0139 REDUCER 19 2 60 0167 2 1 2 0 300 PSI GAUGE 20 1 60 0171 1 4 UNION TEE 21 5 60 0175 1 2 TUBE TO 3 8 NPT M ELBOW 22 1 60 0176 1 2 TUBE UNION TEE 23 3 60 0177 1 2 TUBE X 3...

Page 8: ...returned for inspection Service or Repair Warranty service or repairs must be performed by a Branick designated service company Membranes replaced under warranty will remain under warranty for the re...