![Brandywine 0366003 User Manual Download Page 32](http://html1.mh-extra.com/html/brandywine/0366003/0366003_user-manual_2802105032.webp)
32
MANUAL P/N 900000178 REV B
3.6.3.2
Reference Settings Page 2
Page 2 of the MCM Reference settings subtab contains the settings for input
reference delays, enabling the system to account for cable propagation delay, and
AutoSwitch prevention.
Figure 15. MCM Reference Settings Page 2
Table 6. MCM Reference Settings Page 2 Setting Descriptors
SETTING
DESCRIPTION
Delays
HaveQuick Ref
Adjust the delay compensation for the HaveQuick input
reference in nanoseconds
IRIG-B Ref
Adjust the delay compensation for the IRIG-B input
reference in nanoseconds
1PPS Ref
Adjust the delay compensation for the 1PPS input reference
in nanoseconds
GPS Ref
Adjust the delay compensation for the GPS input reference
in nanoseconds
Summary of Contents for 0366003