16
MANUAL P/N 900000178 REV B
Table 1. M212 Status Page Descriptors
FIELD
DESCRIPTION
TFOM
Time Figure of Merit (TFOM), a numerical rating of the
reliability of the current time output, with 1 being the highest,
and 9 being the lowest
System Time
The current year, day of year, and time that the system is using.
Sys Time Last Set
By
The timing source that last set the system time.
Sys Time Last Let
at
The time that the system time was last set by an external source
Leap Second
Epoch
The date and time of an impending leap second if one is
pending.
Leap Second State Will say whether or not a leap second is pending. Leap second
state can be:
Not Pending
- No Future Leap Second has been announced by
International Earth Rotation and Reference Systems Service
(IERS).
Pending
- A leap second has been announced by IERS but it has
not happened yet.
Past Pending
- A leap second was announced and has already
occurred.
Leap Sec Info Last
Set By
Displays the reference source that a leap second was last set up.
Stratum
The current reference stratum that the M212 is operating in.
Ref Phase Error
The reported phase error of the reference source.
Summary of Contents for 0366003
Page 20: ...20 MANUAL P N 900000178 REV B Figure 5 M212 Settings Tab in Edit Mode...
Page 44: ...44 MANUAL P N 900000178 REV A 5 Front Panel Drawing Figure 24 M212 Front Panel Drawing...
Page 45: ...45 MANUAL P N 900000178 REV A 6 Rear Panel Drawings Figure 25 M212 Rear Panel Drawing...