15
2 / INSTALLING YOUR APPLIANCE
Markings on the injectors
The table below shows where the injectors
are positioned on your appliance according
to the type of gas used.
Each number is marked on the injector.
LPG Gas
Gas rating
Appliance designed for installation in
SINGAPORE
LPG
Hourly input - see below at 15°C at 1013 mbar
G30
28 mbar
EXTERNAL RING
Indicator marked on injector
62B
Nominal heat rating
(kW)
3.50
Low heat rating
(kW)
1.900
Hourly output
(g/h)
254
CENTRAL BURNER
Indicator marked on injector
49B
Nominal heat rating
(kW)
1.00
Low heat rating
(kW)
0.620
Hourly output
(g/h)
73
TOTAL FOR HIGH-POWER HOB
Total nominal heat rating
(kW)
4.50
Maximum output
(g/h)
327
62B
49B
62B
62B
62B
Example :
injector reference 62B
Adjust the retarder on the taps
— Using a small
fl
at-head screwdriver, screw
in the brass burner-power screws (yellow)
all the way, (
fi
g. 1) screwing them in a
clockwise direction.
— Replace the gaskets and the knobs,
paying careful attention to their direction
and ensuring that the knobs are pushed in
all the way.
— Put the burner heads, burner cover and
pan support back in position.
Tap axis
Burner power
adjustment screw
Fig. 01
Summary of Contents for BPG6308 Series
Page 1: ...GUIDEFORINSTALLATIONANDUSE EN Cooking hob BPG6308...
Page 23: ...23...