27
Cable H05VVF - T105
or H05V2V2F - T90
Cross section of
conductors in
mm
2
Fuse
220-240 V
~
- 50 Hz
Gas
3 conductors of
which 1 is to be
earthed.
1
10 A
C
ROSS SECTION OF THE CABLE TO USE
Installing your hob in all simplicity
Hob is delivered with a three-conduc-
tor (phase + earth + neutral) H05VVF
- T105, or H05V2V2F - T90 1mm
section cable ref. AFTER-SALES
SERVICE: 77x3767 (6470.1516) and
must be connected to the mains 220-
240 V monophase by the intermediary
live, earth and neutral (Kite-marked)
or a single pole cut-off device with a
contact opening by at least 3mm.
E
lectrical connections
The protective conductor is connected to the
earth connection on the hob
and therefore must also be connected to an external earth connection
.
Use a 10 A fuse.
If the mains cable is damaged, it must be replaced by a cable or a special unit
available from the manufacturer or his After Sales Service.