703739-1 Revision D Spider Glazier 2200 Operator's Manual Issue Date: 2019-Jan-25
Page 17 of 27
f) Installing Tieback Locking Device
Step 1:
Install 5/8" Shackle on bracket at end of Backspan, as
shown in Figure 14.
Step 2:
Install Sling Link on Shackle.
Step 3:
Loop second 5/8" Shackle through Sling Link and bolt
Tieback Locking Device Bracket to Shackle.
Step 4:
Bolt Tieback Locking Device to Tieback Locking
Device Bracket.
Figure 14: Installing Tieback Locking Device
To Tieback Anchor
5/8" Shackle
5/8" Shackle
Sling Link
Tieback Locking Device Bracket
Tieback Locking Device