Connecting RF-LINK socket 

 

BNC socket to cascade further Compact Transmitter MSI8V. To manage more Outputs you 
can extend the system to more outputs. 

 

 

 

Connecting radiator sockets 

IR-LINE 1 and 2: BNC sockets for connecting INFRACOM® radiators HLN82A and 
HLN82B. Up to 10 radiators can be connected directly to each socket. 

 

 

 

 

 

Connecting mains power 

 

Connect the delivered cable with this socket to ensure the 
proper working of the Compact Transmitter. 

 

 

 

Summary of Contents for MSI8V CDSVAN

Page 1: ...BRÄHLERICS CDSVAN Digital Conference Management System MSI8V Compact Transmitter Operating instructions Ver 1 3 ...

Page 2: ... 100 E Mail sales braehler com You will find further information about our products on the internet at http www braehler com 2003 BRÄHLER ICS AG Königswinter All rights reserved especially also partly the translation reprint reproduction through copying or other similar methods BRÄHLER ICS reserves the right to make changes without notice INFRACOM and DIGIMIC are registered trademarks Operating in...

Page 3: ...erate equipment near heat sources such as heating radiators etc power connection install all power cables to avoid damaging connecting cables avoid trip traps liquids avoid penetration of liquids into the housing exclusively operate equipment via wall sockets that are connected to ground according to the relevant specifications and regulations Warning Never expose equipment to rain or humidity Ple...

Page 4: ...MSI8V CDSVAN 4 ...

Page 5: ...n LINK 12 Connecting the VAN IN socket 12 Connecting the VAN LINK socket 12 Connecting LINE OUT sockets 12 Connecting RF LINK socket 13 Connecting radiator sockets 13 Connecting mains power 13 Starting Up 14 Tuning input output levels 14 OPERATION 15 LED AF and ON on front side 15 Infrared test diodes 15 Overview 16 Applications 17 Appendix 20 Technical Data MSI8V 20 Optional accessories 20 Bloc d...

Page 6: ... important note which has to be followed to guarantee that the functions of the unit the security of any data or your health are not put at risk Indicates additional information remarks and tips Describes activities that must be performed in the shown order Words in bold letters require your special attention ...

Page 7: ...ins power If a voltage conversion is required consult your BRÄHLER ICS dealer or qualified personnel Should any liquid or solid object fall into the cabinet unplug the unit and have it checked by qualified personnel before it will be used again Unplug the unit from the wall outlet or set the Main Power switch to OFF if it is not used for several days To disconnect the cord pull it out holding the ...

Page 8: ... European directive 89 336 EWG Council directive to the alignment of the rules of rights of all member states about the electromagnetic compatibility modified through RL 91 263 EWG 92 31 EWG and 93 68 EWG of the council Further information is available on request The warranty will expire if you cause defectives through inappropriate use or handling of the unit Important information The unit should...

Page 9: ...management system CDSVAN the system can provide the best possible communication facilities for organized events that need to use several languages Each and every participant a term often used is delegate can use the microphone system to speak and what he or she says will be translated simultaneously so that other delegates will be able to listen to it in one of the several languages This technique...

Page 10: ...d signals on the different carrier frequencies and for signal amplification The Compact Transmitter consists of a 19 housing 2HU Eight channels can be transmitted with one MSI8V usually defined as Original 7 languages On the front right hand side of the Compact Transmitter MSI8V there is a POWER switch with a green ON LED which shows whether the transmitter is switched on Next to this there are th...

Page 11: ...to the CDSVAN PC Computer VAN LINK RJ45 socket for cascading Audio with a second MSI8V LINE OUT eight sockets for audio recording RF LINK socket for cascading RF with further MSI8V RADIATORS 2 x BNC sockets for connecting INFRACOM radiators HLN82A and HLN82B Up to 10 radiators can be connected directly at each output Mains power connector ...

Page 12: ...et via DIP switch ON LINK socket not used open OFF LINK socket connected with another Compact Transmitter MSI8V Connecting the VAN IN socket RJ45 for the connection to the CDSVAN PC transmission of the channels The input is balanced via AF transformer Connecting the VAN LINK socket Within a 16 channel system 1 15 the LINK socket can be used to transmit the channels 8 15 to the next MSI8V In this c...

Page 13: ...an extend the system to more outputs Connecting radiator sockets IR LINE 1 and 2 BNC sockets for connecting INFRACOM radiators HLN82A and HLN82B Up to 10 radiators can be connected directly to each socket Connecting mains power Connect the delivered cable with this socket to ensure the proper working of the Compact Transmitter ...

Page 14: ...er as a separate sticker which may be adhering to the front panel OFF ON Ch30 Ch37 OFF ON Ch14 Ch29 OFF ON ChOR Ch13 3 0 3 1 3 2 33 34 35 3 6 3 7 18 19 2 0 2 1 2 2 2 3 2 4 2 5 2 6 2 7 2 8 2 9 1 4 1 5 1 6 17 O R 1 2 3 4 5 6 7 8 9 I F 10 1 1 1 2 1 3 The following allocation is shown on the figure above First figure Channel 1 second figure Channel 16 third figure Channel 32 The left DIP switch will a...

Page 15: ...hannels and system start up LED AF and ON on front side AF This LED indicates a signal on this output for example line 1 ON This LED represents the ON status of the corresponding output channel Remark You should switch off not used channels to increase the IR power ON and OFF status is set with the left DIP switch Infrared test diodes Three transmitting test diodes allow testing the receivers at a...

Page 16: ... switch Illustration 1 AF indicator LED ON LED DIP switch setting channel range Channel selection 3 Test diodes VAN IN LINE OUT channel 1 8 VAN LINK Mains Power Termination LINK Link connector BNC Radiator connectors Illustration 2 ...

Page 17: ...iagram shows a complete application for an eight channel OR 7 interpreter system Monitoring part is the Receiver IRX together with the IR Radiator HLN82B CDSVAN System Components CDSVAN PC Including CDSVAN Software and DSP Hardware MSI8V Compact Transmitter HLN82B Radiator 10W 20W IRX Receiver for up to 32 channels ...

Page 18: ... VAN link VAN IN BNC Ch8 Ch1 IR LINK DATA signal CDSVAN PC Compact Transmitter Application 2 Two Compact Transmitters MSI8V are linked to one system The monitoring part consists of the Receiver IRX together with the IR Radiator HLN82B CDSVAN System Components CDSVAN PC including CDSVAN Software and DSP Hardware MSI8V Compact Transmitter HLN82B Radiator 10W 20W IRX Receiver for up to 32 channels ...

Page 19: ...for a multi channel interpreter system Monitoring part is the Receiver IRX together with the IR Radiator HLN82B CDSVAN System Components CDSVAN PC including CDSVAN Software and DSP Hardware MSI8V Compact Transmitter PSU01 04 Power Supply DOLV Interpreter console for one interpreter HLN82B Radiator 10W 20W IRX Receiver for up to 32 channels ...

Page 20: ...atures Green lighted mains switch for power ON indication Red LEDs for channel switched ON Green LEDs for Audio available AF Transmission frequency 55kHz 1335kHz channel 31 in 40kHz steps Intermediate frequency 455 kHz Measurements Distortion 0 2 Signal to noise ratio 70dB Channel separation 60dB Power Supply Mains power 90 250 VAC 50 60 Hz Power consumption 40VA max Housing 19 2 HE Aluminum silve...

Page 21: ...8 or 16 channels DV9 Delegates Unit DDV9 Delegates Unit for two delegates PSU04 Power Supply Unit up to 4 branches for interpreter consoles delegate units PSU01MA SL Additional Power Supply for interpreter consoles delegate units B8 AD DA Interface 8 channels MotorMixer Remote Mixer with 8 motorised faders RSP8V Digital Distribution Amplifier MSI8V INFRACOM Infrared Transmitter HLN82B INFRACOM Inf...

Page 22: ...cable possibly defective The power switch is not in the correct position Check if there is no connection to the mains power Replace a new mains cable Turn on the POWER ON switch No clear IR signal at the IRX receiver 2 or more channels switched to the same frequency Check frequency setting on front panel and control signal using the test diodes No audio green AF LED does not light up No INT Interp...

Page 23: ...e JW Javanese KN Kanadian KS Kashmiri KK Kazakh RW Kinyarwand Kinyarwanda KY Kirghiz RN Kirundi KO Korean KU Kurdish LO Laothian LA Latin LV Latvian Latvian Lettish LN Lingela LT Lithuanian MK Macedonian MG Malagasy MS Malay ML Malaysiam MT Maltese MA Mandarin MI Maori MR Marathi MO Moldavian MN Mongolian NA Nauru NE Nepali NO Norwegian OC Occitan OR Oriya OM Oromo PS Pashto Pashto Pushto FA Persi...

Page 24: ......

Page 25: ..._______________________________________________________ Phone _________________________________ Fax ________________________________________ Notes Comments _____________________________________________________________________________________ _____________________________________________________________________________________ ________________________________________________________________________...

Page 26: ... 0 2244 930 0 Fax 49 0 2244 930 450 http www braehler com Rental service Wahlfelder Mühle 3 D 53639 Königswinter Tel 49 0 2244 930 200 Fax 49 0 2244 930 430 E Mail rental braehler com Sales Auf der Alten Burg 6 D 53639 Königswinter Tel 49 0 2244 930 100 Fax 49 0 2244 930 450 E Mail sales braehler com Service Tel 49 0 2244 930 0 Fax 49 0 2244 930 400 E Mail cdsvan braehler com ...

Page 27: ......

Page 28: ...BRÄHLERICS Phone 49 2244 930 0 www braehler com BGE MSI8V doc 0703 ...

Reviews: