TDB3104, WF3204
Installation
14
1/15/2013
Bradley
• 215-1078 Rev. T; ECN 12-00-004
5b
Adaptive infrared assembly for B drain and H drain units
without Tie Pipe option
continued...
D
Place the infrared module assembly on top of
sprayhead. Rotate until actuator module locks in
with tie bar. Drop two infrared module wires down
the support tube. Make sure infrared module
windows are facing away from the wall.
Skip to step F for units without soap.
E
For units with soap option, slide the spacer and
soap dispenser over the 1-1/2" pipe.
F
Position the upper tie bar slightly below the module
or soap dispenser and fasten securely to vent pipe
with set screws provided. Secure top cover to tie
bar with two cap screws provided.
G
Connect supply stops onto stub-outs. Connect
flexible hoses to supply stops.
Unit with "B" Drain and IR Module Shown,
Also Available with "H" Drain
Top
Cover
Soap
Dispenser
Spacer
Module
Cover
IR Module
Assembly
(S50-367)
Tie Bar
Sprayhead
(S05-054B)
Support Tube
Standard (S57-005)
TAS/Juv (S57-006)
Valve Assembly
(S45-2504)
3/8" Tube to
Sprayhead
Volume
Control Valve
Do not apply pipe sealant to
compression fittings.
Flexible
Hose
Stop
Thermostatic Mixing
Valve Assembly
Solenoid Valve
Assembly