SN2003/AST4, SN2003/AST4-F, SN2023/AST4
Installation
4
8/24/2020
Bradley
• 215-1072 Rev. L: ECO 20-00-015
Supplies from Above
Supplies from Below or Through Wall
Rough-In Dimensions for Supplies
and Drain
Notes
Maximum flow rate required to washfountain is 1 .5 GPM . Size supply lines
accordingly .
Supplies from Below: Stub up 2-1/2" (64) .
Supplies from Above: Supplies must be located on centers of dimensions
shown to pass through washfountain shroud and sprayhead .
Drain through floor: Stub up 3" (76) .
Type B
Centrally rising vent
(P-Trap furnished
with unit .)
Type O
Off-line vent
(P-Trap supplied by
Installer .)
Type A
Off-line vent
(P-Trap supplied by
Installer .)
Type H
Centrally rising vent
(P-Trap furnished
with unit .)
Top View
Top View
When running supplies and drain through wall, use same horizontal measurements as shown in Top
View. Position openings above the finished floor, at the following dimensions (to center):
1/2" Supply: Nominal Copper Tube
1/2" Supply Through Wall (Optional):
Nominal Copper Tube
1-1/2" NPT Drain
1-1/2" NPT Vent
Key
Drain: Standard Height: 19-1/4" (305)
Juvenile Height: 15-1/4" (387)
Supplies: Standard Height: 12" (305)
Juvenile Height: 8" (203)
(mm)
5"
(127)
5"
(127)
4-1/2"
(114)
2-3/4"
(70)
5"
(127) 8-3/4"
(222)
4-1/2"
(114)
4-1/2"
(114)
2-3/4"
(70)
7-9/16"
(192)
2-3/4"
(70)
27/32"
(21)
27/32"
(21)
7-9/16"
(192)
2-3/4"
(70)
27/32"
(21)
27/32"
(21)
Rough-In Locations for Wall Anchor Bracing
Dimensions are to determine reinforcement
locations. Use fixture as a template for precise
location of 3/8" anchors.
Floor-Mounted
Units Only
13-3/8"
(340)
10"
(254)
9"
(229)
4-3/4"
(121)
14-3/4"*
(203)
24-3/4"*
(629)
32-1/2"*
(826)
H
H
C
C
H
H
C
C
* Subtract 4" (102) from this dimension
for juvenile height model.
CL
CL
CL
8-3/4"
(222)
CL
CL
8" Std
(203)
8-3/8" Juv
(213)