LD-3010 Series
Installation
2
2/27/2020
Bradley
• 215-1219 Rev. Q: ECO 19-08-037B
Supplies Required:
• ½" nominal copper tubing for hot and cold supply piping and 1½" NPT drain piping
• Silicone caulk/sealant for sealing between deck and walls
• For optional mounting brackets:
3
⁄
8
" wall anchors and fasteners with washers suitable for wall construction
• For optional carrier sleeves: in-wall carrier sleeves by others (Josam model #17100-203 or equivalent
recommended; refer to the table below for carrier sleeve requirements) .
• For optional stainless steel access panel: four #10 wall anchors and mounting fasteners (for each cover)
suitable for wall construction
Model #
Carrier Sets
Recommended
Carrier Sleeves
Required
LD-3010 30"
1
2
LD-3010 60"
2
3
LD-3010 90"
2
4
LD-3010 120"
3
6
Basin Model #
Carrier Arm
Spacing (min.)
SL-TO1
22" (559 mm)
SL-TR1
23" (584 mm)
HS-TO1
27½" (699 mm)
HS-TS1
19" (483 mm)
HS-TR1
27½" (699 mm)
WARNING
Make sure that all water supply lines have been flushed and then completely turned off before beginning
installation. Debris in supply lines can cause valves to malfunction.
Turn OFF electrical power to the electrical outlets, then unplug all electrical units prior to installation. Electrical
power MUST remain off until installation is complete. After installation is complete, turn on the water supply
first, then turn on the electrical power.
Installer's hardware must be appropriate for wall construction. Wall anchors must have a minimum pull-out
rating of 1,000 pounds.
IMPORTANT
Read this entire installation manual to ensure proper installation. When finished with the installation, file this
manual with the owner or maintenance department. Compliance and conformity to local codes and ordinances
is the responsibility of the installer. Product warranties may be found under “Products” on our website at
www.bradleycorp.com.
Separate parts from packaging and make sure all parts are accounted for before discarding any packaging
material. If any parts are missing, do not begin installation until you obtain the missing parts.
For standard height mounting, do not exceed the recommended 34" distance from the top of the lav deck to
the finished floor. To meet ADA requirements, the lav deck cannot exceed the 34" maximum height dimension.