Supplies Required

• Shut-off on the outlet if tempered water is supplied to a remote location

• Shut-off on the inlets/supplies

• (2) #10 fasteners (and wall anchors, if necessary) for wall bracket

2

Adjust Temperature with Water Running

3

Test Unit

Shut the hot water inlet off by closing hot water inlet valve. While the hot water supply is turned off, check to make sure the cold 

water flow is reduced. If the cold water is reduced properly, reopen the hot water supply.

Shut the cold water inlet off by closing the cold water inlet valve. While the cold water supply is off, check to make sure that the hot 

water flow has shut down.

1

Connect Supply Lines

Use only teflon tape or sealant appropriate for plastic 

threads. Do not use pipe dope or thread lock. 

H

C

A

Loosen Cap Screw about 1/4" (4-6 turns) 

and lift up cover (do not remove).

B

Using cover, turn cartridge gently until 

desired water temperature is reached. Do 

not turn past stops as this may damage 

unit. Push cover down and tighten screw. 

DO NOT SKIP THIS STEP!!!

Tools Required

• Adjustable Wrench

• Needle-Nose Pliers

• Phillips-Head Screwdriver

This valve is NOT factory preset. Upon installation, the temperature of this 

valve must be checked and adjusted to ensure delivery of a safe water 

temperature. Water in excess of 110°F (43°C) may cause scalding.

COLD

Mix  

(to Faucet)

HOT

COLD

HOT

Mix  

(to Faucet)

S59-4000, S59-4000A

S59-4000BY