S59-4000, S59-4000A, S59-4000BY
Installation
2
4/16/2014
Bradley
• 215-1638 Rev.
E ECN 14-09-013B
Supplies Required
• Shut-off on the outlet if tempered water is supplied to a remote location
• Shut-off on the inlets/supplies
• (2) #10 fasteners (and wall anchors, if necessary) for wall bracket
2
Adjust Temperature with Water Running
3
Test Unit
Shut the hot water inlet off by closing hot water inlet valve. While the hot water supply is turned off, check to make sure the cold
water flow is reduced. If the cold water is reduced properly, reopen the hot water supply.
Shut the cold water inlet off by closing the cold water inlet valve. While the cold water supply is off, check to make sure that the hot
water flow has shut down.
1
Connect Supply Lines
Use only teflon tape or sealant appropriate for plastic
threads. Do not use pipe dope or thread lock.
H
C
A
Loosen Cap Screw about 1/4" (4-6 turns)
and lift up cover (do not remove).
B
Using cover, turn cartridge gently until
desired water temperature is reached. Do
not turn past stops as this may damage
unit. Push cover down and tighten screw.
DO NOT SKIP THIS STEP!!!
Tools Required
• Adjustable Wrench
• Needle-Nose Pliers
• Phillips-Head Screwdriver
This valve is NOT factory preset. Upon installation, the temperature of this
valve must be checked and adjusted to ensure delivery of a safe water
temperature. Water in excess of 110°F (43°C) may cause scalding.
COLD
Mix
(to Faucet)
HOT
COLD
HOT
Mix
(to Faucet)
S59-4000, S59-4000A
S59-4000BY