FL-2H, FL-2L
Installation
8
2/15/2012
Bradley Corporation • 215-1512 Rev. G; ECM 11-08-011
2
Lavatory Deck
Backing Information
16"
(406mm)
Metal Studs
Drywall
66"
(1676mm)
12"
(305mm)
25"
(635mm)
Securely fasten
plywood to at
least (3) metal
studs (plywood
to equal thickness
of drywall, ½"
minimum
Use
3
⁄
8
" toggle bolts
and washers to
secure the support
bracket to plywood
(2) places.
Refer to the rough-ins to determine wall-mounting location for
optional mixing valve.
Installer may prefer to install the faucet before mounting the
fixture to the wall.
If necessary, adjust the fixture height
before securing to the support brackets.