background image

Express® Deck Lavatory System EXD Series

Installation Instructions - For Service Only

EXD-3/WH97

7

Bradley Corporation • 

215-1278 Rev. C; EN 03-817

6/8/04

Installation Instructions

continued . . . 

Step 4: Connecting supply and drain

1. FOR HOT AND COLD SUPPLY: Connect the Vernatherm™ Thermostatic Mixing Valve as

shown in Figure 5a. 

NOTE: The red marking on Vernatherm™ Mixing Valve indicates hot water supply inlet. 

FOR SINGLE TEMPERED SUPPLY: Attach the stop/check/strainer to the 1/2" tempered supply
line. Connect the stop/check/strainer to the flexible supply hose (see Figure 5b).

FOR INFRARED FAUCET OPTION ONLY: Attach the stop/check/strainer to the 1/2" tempered
supply line. Connect the stop/check/strainer to the solenoid valves with the flexible supply hose
(see Figure 5b).

2. Install the two drain plugs in the two holes in the bottom of the bowl (see Figure 6).

3. Beneath the bowl, install the 1/4" rubber washers onto the drain plugs, and thread the waste tee

to the drain plugs.

4. Assemble the P-trap by connecting the 1-1/2" tubular pipe to the waste tee and to the 1-1/2"

drain pipe stubbed out of the wall.

5. Install the strainer on the drain plug opening inside the bowl, and push the strainer firmly into

place.

#8 SCREW

BOWL

DRAIN

PLUG

PLUG

RUBBER

WASHER

WASTE SHOE

WASTE TEE

Figure 6

Figure 5b

7-5/8"

(194mm)

1/2"-14 NPT

SUPPLIED BY

INSTALLER

THERMOSTATIC

MIXING VALVE

(S01-116)

COLD SUPPLY

STOP/STRAINER

CHECK VALVE

(S60-003)

TAILPIECE (129-007)

NUT (110-005)

WASHER (124-001AF)

HOT SUPPLY

Figure 5a

Summary of Contents for Express EXD Series

Page 1: ...making connections Debris in supply lines will cause the valves to malfunction Turn OFF electrical power to the outlet when installing the Express Deck Wall anchors used must have a minimum pull out r...

Page 2: ...ess Deck Lavatory System EXD Series EXD 3 WH97 Installation Instructions For Service Only 2 6 8 04 Bradley Corporation 215 1278 Rev C EN 03 817 EXD 3 WH97 Express Deck Dimensions Standard Height Mount...

Page 3: ...ion Step 1 Rough in IMPORTANT Dimensions in Figure 1a are for a Standard Height Express Deck only See Figure 1b on page 4 for Juvenile Height Express Deck 1 Rough in 1 2 NPT hot and cold supply lines...

Page 4: ...xpress Deck Lavatory System EXD Series EXD 3 WH97 Installation Instructions For Service Only 4 6 8 04 Bradley Corporation 215 1278 Rev C EN 03 817 Figure 2 Figure 1b Juvenile Height Mounting EXD 3 WH9...

Page 5: ...el IMPORTANT Anchoring the frame to a wall that is not flat may cause the frame to bend If necessary install shims to compensate for any wall distortion 3 Ensure that the back of the frame is flat aga...

Page 6: ...e the bowl assembly squarely onto the frame 2 Attach the front of the bowl assembly to the frame using the four 1 4 20 x 3 8 pan head screws and washers provided Do not tighten screws at this time IMP...

Page 7: ...2 tempered supply line Connect the stop check strainer to the solenoid valves with the flexible supply hose see Figure 5b 2 Install the two drain plugs in the two holes in the bottom of the bowl see...

Page 8: ...amp cloth and a household liquid detergent Stubborn stains can be removed as follows 1 Using a 7448 Scotch Brite pad scrub with an abrasive cleanser such as Ajax Comet or Soft Scrub and water 2 Clean...

Page 9: ...Frame and Panel Assembly of Components STOP STRAINER CHECK VALVE S60 003 90 ELBOW 169 639 BRASS PIPE NIPPLE 113 006DJ 7 5 8 194mm 1 2 14 NPT SUPPLIED BY INSTALLER THERMOSTATIC MIXING VALVE S01 116 CO...

Page 10: ...replace with a new ring NOTE An old or worn flip ring may cause temperature fluctuation and or water chatter 3 Reassemble the power element and valve body Apply grease to the main valve slide and gen...

Reviews: