background image

Express

®

Crescent

®

Lavatory System - CRS-Series

CRS-2/IR, CRS-3/IR

Installation Instructions

14

2/8/07

Bradley Corporation • 215-1330 Rev. K; EN 06-915

Vernatherm™ Thermostatic Mixing Valve (S01-524)

S

trainer

173-028

Tempered Line Adapter Assembly (S39-685) Option

Thermostat

5

1

7

1

O-Ring

8

1

O-Ring

Item

Qty

Description

Repair Kit S65-259

9

6

5

4

3

2

1

7

8

S

trainer

(173-028)

Valve Body

S

pring

Thermostat

Piston

S

tem

O-Ring

O-Ring

Cap

Nut 3/8-24 Hex Jam

10

S

eal Cup

11

Figure 9

Figure 10

Summary of Contents for Express Crescent CRS-2/IR

Page 1: ...installation manual 215 1583 NOTE 3 station unit is shown throughout 2 station is similar A D A C O M PLIANT IMPORTANT Read this entire installation manual to ensure proper installation then file the...

Page 2: ...2 216 mm mm mm 3 3 8 86 17 3 8 441 14 356 48 1219 26 660 ADJUSTMENTS TO VERTICAL DIMENSIONS FOR VARIOUS RIM HEIGHTS Rim Height Application Adjustment 34 Adult Height ADA None as shown TAS Adult Heigh...

Page 3: ...Figure 1 below and Figure 2 on page 4 for Express Crescent Lavatory System rough ins and dimensions 1 Rough in 1 2 NPT hot and cold supply lines and 1 1 2 NPT drain waste connection through wall at d...

Page 4: ...protected electrical outlet per local code at the location shown in Figure 2 3 Install six 3 8 wall anchors with a minimum pull out rating of 1 000 lbs supplied by installer at the locations marked in...

Page 5: ...Figure 1 Use Trap Cover to locate 5 OPTIONAL SOAP TANK Install 1 4 anchors for soap tank installation refer to soap system installation manual 215 1583 for further instructions Step 4 Remove cover fro...

Page 6: ...p check valve to the 1 2 tempered supply line Connect the stop check valve to the solenoid valve with the flexible supply hose NOTE The thermostatic mixing valve requires at least 115 F water from the...

Page 7: ...uit plug from the bowl into the solenoid circuit plug located on the valve bracket 2 Snap the transformer circuit plug into the female transformer circuit plug located on the valve bracket 3 Turn on t...

Page 8: ...emperature see Figure 7 Once desired temperature is reached tighten nut to prevent temperature change Express Crescent Lavatory System CRS Series CRS 2 IR CRS 3 IR Installation Instructions 8 2 8 07 B...

Page 9: ...ensers see 215 1583 Step 10 Install the top cover 1 Carefully place the top cover on top of the lavatory system bowl 2 Install the threaded rods into the holes on the bottom of the top cover see Figur...

Page 10: ...4 is for spray paint Motsenbocker s LIFT OFF can be ordered through Sanitary Maintenance Service Inc call 1 800 451 5523 ext 425 or visit www sanitarymaintenance com product htm for ordering informat...

Page 11: ...body Tighten until the armature plate makes contact with the plastic body 4 Reconnect the wiring per diagram on page 7 for CRS 2 IR or page 8 for CRS 3 IR Problem An individual operating station fails...

Page 12: ...IPTION QTY PART NO REF 1 1 118 307 VALVE BODY 1 4 CLOSED 2 1 269 983 DIAPHRAGM 3 1 269 577 ARMATURE 4 1 269 578 SPRING 5 1 269 1729 ARMATURE HOUSING 6 1 269 1730 CLAMP ARMATURE HOUSING 7 1 269 579 COI...

Page 13: ...itable for brass and stainless steel may be used if cleaning with suitable cleaner is not sufficient to remove debris a 400 grit sandpaper may be used to polish and hone the piston and valve body Snap...

Page 14: ...6 915 Vernatherm Thermostatic Mixing Valve S01 524 Strainer 173 028 Tempered Line Adapter Assembly S39 685 Option Thermostat 5 1 7 1 O Ring 8 1 O Ring Item Qty Description Repair Kit S65 259 9 6 5 4 3...

Reviews: