Thermostatic Mixing Valve Troubleshooting

NOTE: Before attempting to troubleshoot the valve or disassemble the components, check for the
following conditions:

• If stop/check valves are used, make sure that they are fully open.
• Make sure that the hot and cold inlet pipes are connected properly, and that there are no cross-

connections or leaking stop/check valves.

•  Check the hot water heater output to make sure that it is at least 20° F above the set

temperature.

Be sure to close the appropriate shut-off valves prior to disassembly of the valve and reopen the
valves after inspection and repair is complete.

Problem: Limited water flow

Cause: Dirt and debris have built up in the valve or strainer.

1. Remove and clean strainer (see Figure 9 or 10 on page 14). If strainer needs to be replaced, order

Bradley part number 173-028.

2. Check the piston for smooth movement.

To check the valve's piston for free and smooth movement, follow the procedures outlined below:

1. Remove the valve's cap and thermostat (see Figure 9 on Page 14).
2. Push down on the piston with your finger (the piston should move freely). If the movement is

not as it should be, the piston needs to be cleaned. Follow the method outlined below for
cleaning the piston and valve body:
• Remove the thermostat.
• Lift the piston out with a needle-nose pliers and remove the spring.
• Any cleaner suitable for brass and stainless steel may be used (if cleaning with suitable cleaner

is not sufficient to remove debris, a 400-grit sandpaper may be used to polish and hone the
piston and valve body).

• Snap spring into piston (will detent) and reassemble into the valve body. Retest the piston.

3. If, after a thorough cleaning, the piston does not move freely, the piston must be replaced.

Contact your Bradley representative and ask for Repair Kit (part number S65-259).

Problem: External leaks in the system

Cause: O-rings have been damaged.

Solution: Replace O-rings where necessary. For replacement of the O-rings, contact your 

Bradley representative and ask for Repair Kit (part number S65-259).

Problem: Improper water temperature or temperature fluctuation

Cause: Thermostat is slowly failing or not working at all.

Solution: Check the thermostat for proper operation.

1. At room temperature (80° F or less) remove cap and thermostat.
2. Place thermostat into container with 115° F water. The pushrod should pop out of the 

thermostat approximately 1/10".

3. If thermostat pushrod does not pop out, the thermostat must be replaced. Contact your Bradley

representative and ask for Repair Kit (part number S65-259).

Cause: Valve temperature is not properly set.

Solution: Adjust the temperature. Using a blade screwdriver, turn the adjustment stem

counterclockwise

to 

increase

the temperature or 

clockwise

to 

decrease

the temperature.

Express

®

Crescent

®

Lavatory System - CRS-Series

Installation Instructions

CRS-2/IR, CRS-3/IR

13

Bradley Corporation • 215-1330 Rev. K; EN 06-915

2/8/07

Summary of Contents for Express Crescent CRS-2/IR

Page 1: ...installation manual 215 1583 NOTE 3 station unit is shown throughout 2 station is similar A D A C O M PLIANT IMPORTANT Read this entire installation manual to ensure proper installation then file the...

Page 2: ...2 216 mm mm mm 3 3 8 86 17 3 8 441 14 356 48 1219 26 660 ADJUSTMENTS TO VERTICAL DIMENSIONS FOR VARIOUS RIM HEIGHTS Rim Height Application Adjustment 34 Adult Height ADA None as shown TAS Adult Heigh...

Page 3: ...Figure 1 below and Figure 2 on page 4 for Express Crescent Lavatory System rough ins and dimensions 1 Rough in 1 2 NPT hot and cold supply lines and 1 1 2 NPT drain waste connection through wall at d...

Page 4: ...protected electrical outlet per local code at the location shown in Figure 2 3 Install six 3 8 wall anchors with a minimum pull out rating of 1 000 lbs supplied by installer at the locations marked in...

Page 5: ...Figure 1 Use Trap Cover to locate 5 OPTIONAL SOAP TANK Install 1 4 anchors for soap tank installation refer to soap system installation manual 215 1583 for further instructions Step 4 Remove cover fro...

Page 6: ...p check valve to the 1 2 tempered supply line Connect the stop check valve to the solenoid valve with the flexible supply hose NOTE The thermostatic mixing valve requires at least 115 F water from the...

Page 7: ...uit plug from the bowl into the solenoid circuit plug located on the valve bracket 2 Snap the transformer circuit plug into the female transformer circuit plug located on the valve bracket 3 Turn on t...

Page 8: ...emperature see Figure 7 Once desired temperature is reached tighten nut to prevent temperature change Express Crescent Lavatory System CRS Series CRS 2 IR CRS 3 IR Installation Instructions 8 2 8 07 B...

Page 9: ...ensers see 215 1583 Step 10 Install the top cover 1 Carefully place the top cover on top of the lavatory system bowl 2 Install the threaded rods into the holes on the bottom of the top cover see Figur...

Page 10: ...4 is for spray paint Motsenbocker s LIFT OFF can be ordered through Sanitary Maintenance Service Inc call 1 800 451 5523 ext 425 or visit www sanitarymaintenance com product htm for ordering informat...

Page 11: ...body Tighten until the armature plate makes contact with the plastic body 4 Reconnect the wiring per diagram on page 7 for CRS 2 IR or page 8 for CRS 3 IR Problem An individual operating station fails...

Page 12: ...IPTION QTY PART NO REF 1 1 118 307 VALVE BODY 1 4 CLOSED 2 1 269 983 DIAPHRAGM 3 1 269 577 ARMATURE 4 1 269 578 SPRING 5 1 269 1729 ARMATURE HOUSING 6 1 269 1730 CLAMP ARMATURE HOUSING 7 1 269 579 COI...

Page 13: ...itable for brass and stainless steel may be used if cleaning with suitable cleaner is not sufficient to remove debris a 400 grit sandpaper may be used to polish and hone the piston and valve body Snap...

Page 14: ...6 915 Vernatherm Thermostatic Mixing Valve S01 524 Strainer 173 028 Tempered Line Adapter Assembly S39 685 Option Thermostat 5 1 7 1 O Ring 8 1 O Ring Item Qty Description Repair Kit S65 259 9 6 5 4 3...

Reviews: