Collector Cover Installation Procedure
Step 1.
Remove old silicone from top surface of collector flange and collector cover.
Step 2.
Apply ¼" bead of Ultra Copper Silicone around entire collector flange surface. Allow
caulk to “cure” for 10 minutes.
Step 3.
Carefully reinstall collector cover, tighten screws evenly.
Step 4.
Allow a minimum of 6 hours before putting heater back in service.
Apply ¼" bead of Ultra
Copper Silicone around entire
collector flange surface
77