Is igniter resistance
less than 150 Ohms
(cold)?
(see “check igniter
resistance” below)
Refer to ignition module illustration below,
is there 120VAC across terminals
P6(1)
and
P6(2)?
(Check during igniter warm up period,
indicated by the igniter LED glowing on the
ignition module).
Y
N
Replace
hot surface igniter
(see “Hot Surface
Igniter Replacement
Procedure”)
Replace ignition module.
(see “Ignition Module
Replacement
Procedure”)
N
Check harness
connection from igniter
to ignition module.
Y
Hot surface Igniter Testing Procedure
Volt meter set to
OHM setting
Meter probe
Hot surface
igniter
CHECK IGNITER
RESISTANCE
IGNITION MODULE
WARNING
120 volt potential exposure. Use caution
making voltage checks to avoid
personal injury. Igniter may be too hot
to handle, take necessary precautions
60